Page 24 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Biblio-
graphy
graphy
Add
the following standards:
EN 50332-1:2000, Sound system equipment: Headphones and earphones
associated with portable audio equipment — Maximum sound pressure level
measurement methodology and limit considerations — Part 1: General method
for "one package equipment"
associated with portable audio equipment — Maximum sound pressure level
measurement methodology and limit considerations — Part 1: General method
for "one package equipment"
prEN 50332-2 (under consideration), Sound system
equipment: Headphones and earphones associated with portable audio
equipment — Maximum sound pressure level measurement methodology and
limit considerations — Part 2:
equipment — Maximum sound pressure level measurement methodology and
limit considerations — Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers
manufacturers
N/A
Add
the following notes for the standards indicated:
IEC 60130
NOTE Parts 9 and 17:1998 are harmonized as ENs (not modified).
IEC 60169
NOTE Partly harmonized in the EN 60169/HD 134 series (not modified).
IEC 60173
NOTE Harmonized as HD 27 S1:1978 (not modified).
IEC 60335-2-56
NOTE Harmonized as EN 60335-2-56:1997 (not modified)
.
IEC 60335-2-82
NOTE Harmonized as EN 60335-2-82:2000 (not modified)
.
IEC 60695
NOTE Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE Harmonized as EN 61040:1992 (not modified).
IEC 61558-2-1
NOTE Harmonized as EN 61558-2-1:1997 (not modified).
IEC 61558-2-4
NOTE Harmonized as EN 61558-2-4:1997 (not modified).
IEC 61558-2-6
NOTE Harmonized as EN 61558-2-6:1997 (not modified).
Pass
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Class II
N/A
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Pass
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
Pass
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
N/A