                                                                   Page 23 of 67                        Report No. JSH007120244-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
6.1 
(Cont) 
The amount of ionizing radiation is regulated by 
European Council Directive 96/29/Euratom of 13 
May 1996. This directive requires that at any 
point 10 cm from the outer surface of the 
apparatus, the dose-rate shall not exceed 
1µSv/h (0,1 mR/h) taking account of the 
background level. 
Moreover, the measurement shall be made under 
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is 
maintained for 1 h, at the end of which the 
measurement is made. 
A picture is considered to be intelligible if the 
following conditions are met: 
- a scanning amplitude of at least 70 % of the 
usable screen width; 
- a minimum luminance of 50 cd/m² with locked 
blank raster provided by a test generator; 
- a horizontal resolution corresponding to at least 
1,5 MHz in the centre, with a similar vertical 
degradation; 
- not more than one flashover per 5 min. 
 N/A 
13.3.1 
Delete note 4. 
 
Pass 
14 
Delete note 4 and note 5. 
 
Pass 
15.1.1 
Delete note 1 and note 2. 
 
Pass 
15.2 
Delete note 2. 
 
Pass 
16.1 
Delete note 1. 
 
Pass 
16.2 
Delete the note. 
 
Pass 
20 
Delete note 2. 
 
Pass 
Annex B 
Replace note 1 by: 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
 N/A 
 
Annex G 
Delete the note. 
 
N/A 
Annex J.2  Delete the notes of Table J.1 
 
N/A  
Annex N 
Add after the introduction: 
For ROUTINE TEST reference is made to EN 
50333. 
 N/A 
Page of 69
Display