Page 57 of 81  
 
       Floor standing EUT 
The EUT was put on a 0.1m high wooder support, standing on the ground reference  
plane(GRP) 2.6m by 1.8m, made by aluminuim 0.5mm thick. 
 
A vertical coupling plane (VCP) 0.5m by 0.5m in size, the same material type and thickness as that  
of  the ground reference plane was applied ,and was connected to the GRP via a 470k
Ω resistor at  
each end. 
 
The distance between EUT and any of the other metallic surface excepted the GRP, HCP & VCP  
was greater than 1m. 
 
The EUT was arranged and connected according to its functional requirements. 
14.3.2 Test Procedure 
 
The EUT was arranged and connected according to its functional requirements 
Direct static electricity discharges was applied only to those points and surface which are 
accessible to  
personnel during normal usage. 
The test voltage was increased from the minimum to the selected test level and with single 
discharge.  
On each preselected points 10 times of each polarity single discharge were applied  
The time interval between successive single discharges is 1s. 
The ESD generator was held perpendicular to the surface to which the discharge is applied. The  
discharge return cable of the generator was kept at a distance of 0.2m whilst the discharge is being  
applied. During the contact discharges, the tip of the discharge electrode was touch the EUT before  
the discharge switch is operated. During the air discharges, the round discharge tip of the discharge  
electrode was approached as fast as possible to touch the EUT. 
After each discharge, the ESD generator was removed from the EUT, the generator is then 
retriggered  
for a new single discharge.  
Indirect discharge was conducted to objects placed near the EUT, simulated by applying the 
dischares  
of the ESD generator to a coupling plane, in the contact discharge mode. 
10 times of each polarity single discharge were applied to HCP and VCP. The detail selected 
points are  
listed in the following table. 
14.3.3 Photo For Test Set-up 
         none 
14.4 Test Protocol 
 
Temperature  : 
23
°C  
Relative Humidity: 
34% 
 
Direct discharge was applied at the following selected points: 
Test point 
Test level 
[kV] 
Air/ 
Contact 
Polarity 
(+/-) 
Pass/ 
Fail 
Comment 
Contact 
+/- 
All touchable screws of 
enclosure 
Contact 
+/- 
Accessible metal parts of the 
EUT 
Air 
+/- 
Air gap of the switch, button 
Air 
+/- 
The air in-taking opening 
Air 
+/- 
Slots around the EUT 
 
Page of 82