Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T502 basic insulation
minimum 5.5 mm between
T502 core and primary,
Supplementary insulation
minimum 4.5mm between
T502 core and secondary.
Reinforce insulation minimum
9.5mm between T502 primary
and secondary.
minimum 5.5 mm between
T502 core and primary,
Supplementary insulation
minimum 4.5mm between
T502 core and secondary.
Reinforce insulation minimum
9.5mm between T502 primary
and secondary.
T503 basic insulation
minimum 4.0 mm between
T503 core and primary,
Supplementary insulation
minimum 4.0mm between
T503 core and secondary.
Reinforce insulation minimum
8.0mm between T503 primary
and secondary.
minimum 4.0 mm between
T503 core and primary,
Supplementary insulation
minimum 4.0mm between
T503 core and secondary.
Reinforce insulation minimum
8.0mm between T503 primary
and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II construction
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No such components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
Pass
Protective devices used within their ratings
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Fuse F501: 3.8mm
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such device within the
EUT
EUT
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A