Page 12 of 69
Report No.: SH10011244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: TTRF_IECEN 60065I
TRF originator Intertek ETL SEMKO shanghai
14.3.3 Constructional
requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table)
Pass
14.3.3.2
Transformers meet the constructional
requirements
requirements
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T502 basic insulation
minimum 5.5 mm between
T502 core and primary,
Supplementary insulation
minimum 4.5mm between
T502 core and secondary.
Reinforce insulation minimum
9.5mm between T502 primary
and secondary.
minimum 5.5 mm between
T502 core and primary,
Supplementary insulation
minimum 4.5mm between
T502 core and secondary.
Reinforce insulation minimum
9.5mm between T502 primary
and secondary.
T503 basic insulation
minimum 4.0 mm between
T503 core and primary,
Supplementary insulation
minimum 4.0mm between
T503 core and secondary.
Reinforce insulation minimum
8.0mm between T503 primary
and secondary.
minimum 4.0 mm between
T503 core and primary,
Supplementary insulation
minimum 4.0mm between
T503 core and secondary.
Reinforce insulation minimum
8.0mm between T503 primary
and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II construction
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A