HS 2X0 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon HS 2X0 (serv.man2) EMC - CB Certificate online

 
          Page 12 of 69 
      Report No.: SH10011244-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  TTRF_IECEN 60065I 
       TRF originator Intertek ETL SEMKO shanghai 
 
14.3.3 Constructional 
requirements 
 
Pass 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(see appended table) 
Pass 
14.3.3.2 
Transformers meet the constructional 
requirements 
 Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T502 basic insulation 
minimum 5.5 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 4.5mm between 
T502 core and secondary. 
Reinforce insulation minimum 
9.5mm between T502 primary 
and secondary. 
T503 basic insulation 
minimum 4.0 mm between 
T503 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T503 core and secondary. 
Reinforce insulation minimum 
8.0mm between T503 primary 
and secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T502 bobbin: 0.8mm min. 
T503 bobbin: 0.8mm min. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
N/A 