                                                                  Page 7 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 
Withstand 4240Vp test. 
Pass 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
         
 
N/A 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
         
 
N/A 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
Live wires are double 
insulated, no secondary wire 
can come closer to live parts 
Pass 
8.11 
Detaching of wires 
         
 
N/A 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
Mating lock connector used for 
mains. No risk of detached. 
N/A 
 
Vibration test carried out  ........................................ : No, see above 
N/A 
8.12 Void 
 
 N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 Pass 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
 Pass 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
Internal wires secured and 
keep enough distance from 
sharp or hot parts. 
Pass 
8.16 
Only special supply equipment can be used 
 N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
 
Pass 
8.19.1 
Disconnect device 
Mains plug or appliance 
coupler. 
Pass 
 
All-pole switch or circuit breaker with >3mm 
contact separation 
Not used as a disconnect 
device 
N/A 
8.19.2 
Mains switch ON indication 
Not used as a disconnect 
device 
N/A 
8.20 
Switch not fitted in the mains cord 
 
Pass 