                                                                  Page 6 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
         
 N/A 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
 Pass 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
 Pass 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
T502, T503, R558 
Pass 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
CY501, CY502, CY503, 
CY504 
Pass 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
No such voltage 
N/A 
 
Reinforced or double insulation between circuits 
operating at voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 120 V d.c. and 
hazardous live parts at higher voltage 
 N/A 
 
Separation by Class II isolating transformer 
 
N/A 
 
Separation by Class I transformer 
 
N/A 
 
Separation by earthed conductive part 
 
N/A 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) :  
N/A 
 
Reinforced insulation > 0,4 mm (mm) .................... : T502 bobbin: 0.8mm min. 
T503 bobbin: 0.8mm min. 
Optocoupler U502, U504, 
U505, U515: 0.40mm min. 
Enclosure (front panel): 1.5mm 
min. 
Separation sheet on internal 
enclosure around power board: 
0.41mm min. 
Pass 
 
Thin sheet insulation 
Inside T502, T503. 
Pass 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 N/A 
Page of 66