HS 200 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 10

Read Harman Kardon HS 200 (serv.man4) EMC - CB Certificate online

 
Page 9 of 64                        Report No. JSH006110388-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. 
after surge test for basic and 4 MΩ min. for 
reinforced insulation ...........................................:
 N/A 
10.2 
Humidity treatment 48 h or 120 h .......................: 48h, 30℃, 93%R.H. 
Pass 
10.3 
Insulation resistance and dielectric strength 
(See appended table) 
Pass 
 
11 FAULT 
CONDITIONS 
 
11.1 
No shock hazard under fault condition 
         
 
Pass 
11.2 
Heating under fault condition 
(See appended table) 
Pass 
 
No hazard from softening solder 
 
Pass 
11.2.1 
Measurement of temperature rises 
 
Pass 
11.2.2 
Temperature rise of accessible parts 
 
Pass 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(See appended table) 
Pass 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards 
(PCB) to 20.1.3, exceeding the limits of table 3 
by not more than 100 K for an area not greater 
than 2 cm² 
 N/A 
 
b) Temperature rise of printed circuit boards 
(PCB) to 20.1.3 up to 300 K for an area not 
greater than 2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
         
 
N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
         
 Pass 
11.2.5 
Temperature rise of windings 
(see appended table) 
Pass 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table) 
Pass 
 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
3.9kg 
N/A 
Page of 65