Read Harman Kardon HS 200 (serv.man4) EMC - CB Certificate online
Page 13 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
T502 basic insulation
minimum 7.0 mm between
T502 core and primary,
Supplementary insulation
minimum 4.8mm between
T502 core and secondary.
minimum 7.0 mm between
T502 core and primary,
Supplementary insulation
minimum 4.8mm between
T502 core and secondary.
T503 basic insulation
minimum 4.9 mm between
T503 core and primary,
Supplementary insulation
minimum 5.4mm between
T503 core and secondary.
minimum 4.9 mm between
T503 core and primary,
Supplementary insulation
minimum 5.4mm between
T503 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
Class II construction
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No such components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested
as part of the submission
as part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested
as part of the submission
as part of the submission
N/A
14.5 Protective
devices
Pass
Protective devices used within their ratings
Pass
External clearances and creepage distances
meet requirement of clause 13 for the voltage
across the device when opened
meet requirement of clause 13 for the voltage
across the device when opened
Fuse F501: 3.8mm
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such components
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
No such components
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
Click on the first or last page to see other HS 200 (serv.man4) service manuals if exist.