Read Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate online
page 35 of 51
Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
conditions.
8.6
(9.3.4)*
Delete the note "A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
This is not in IEC 60065:2001.
Noted
10.2
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
Adopt the testing conditions designed for tropical
conditions.
120h at a relative humidity of
93%, ambient temperature
40
93%, ambient temperature
40
o
C
Pass
16
External flexible cords
Delete "IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V" and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords" whenever they
appear in this clause.
Delete "IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V" and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords" whenever they
appear in this clause.
Noted
16.2
Delete the notes in small print and insert "A
nominal cross-sectional area of 0.75 mm
nominal cross-sectional area of 0.75 mm
2
will
satisfy this requirement".
Noted
16.3b
(16.4b)*
Delete "Subclause 3.1 of IEC Publication 227-2:
Part 2: Test Methods" and insert "Subclause 9.1
of SS 236":
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
Screene cords in accordance with Table 7 shall
be tested before application of the screen and
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
Part 2: Test Methods" and insert "Subclause 9.1
of SS 236":
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
Screene cords in accordance with Table 7 shall
be tested before application of the screen and
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
Noted
Click on the first or last page to see other HS 100 EU (serv.man14) service manuals if exist.