HS 100 EU (serv.man14) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 36

Read Harman Kardon HS 100 EU (serv.man14) EMC - CB Certificate online

 
 
page 35 of  51 
Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
conditions. 
8.6 
(9.3.4)* 
Delete the note "A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC". 
This is not in IEC 60065:2001. 
Noted 
10.2 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
120h at a relative humidity of 
93%, ambient temperature 
40
o
Pass 
16 
External flexible cords 
Delete "IEC Publication 227: Polyvinyl Cloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC Publication 245: 
Rubber Insulated Cables of Rated Voltage up to 
and including 450/750V" and insert "Singapore 
Standard 236: Flexible Cords", whenever they 
appear in this clause. 
Delete "CEE Publication 13, CEE Publication 2 
and IEC Publication 173: Colours of the Cores of 
Flexible Cables and Cords" whenever they 
appear in this clause. 
 Noted 
16.2 
Delete the notes in small print and insert "A 
nominal cross-sectional area of 0.75 mm
2
 will 
satisfy this requirement". 
 Noted 
16.3b 
(16.4b)* 
Delete "Subclause 3.1 of IEC Publication 227-2: 
Part 2: Test Methods" and insert "Subclause 9.1 
of SS 236": 
9.1 Flexing Test (except for tinsel cords, twisted 
twin and single core cords). 
The test shall be carried out by mieans of the 
apparatus shown in Figure 5. This apparatus has 
a carrier C supporting two pulleys A and B 
arranged so that the cord is horizontal between 
the pulleys. The carrier moves backward and 
forward over a distance of 1 m at an 
approximately constant speed of 0.33 m/s. 
A sample of flexible cord fabout 5 m long shall be 
stretched over the pulleys as shown in the figure, 
each end being loaded with a weight. The weight 
and the diameter of the pulleys A and B shall be 
as given in Table 1. 
Screene cords in accordance with Table 7 shall 
be tested before application of the screen and 
outer sheath. 
The pulleys shall have a semi-circular shaped 
groove for circular cords and a flat groove for 
parallel twin cords. The 
restraining clamps D shall be fixed so that the pull 
is always applied by the weight from which the 
carrier is mowing away. The carrier shall make 30 
000 backward and forward movements (60 000 
single strokes). Each conductor of the sample 
 Noted 
Page of 52
Display