Ref. No. : JSH05090075-001
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No: IEC/EN 60065D
TRF originator BEAB
D6 short circuit, power consumption <2.5W, circuit protected. No high
temperature, no hazard.
temperature, no hazard.
- -
EC5 short circuit, power consumption <1W, circuit protected. No high
temperature, no hazard.
temperature, no hazard.
- -
D7 short circuit, power consumption 37W, no audio output on speaker. No high
temperature, no hazard. Monitored point: winding of TR1
temperature, no hazard. Monitored point: winding of TR1
55 130
EC7 short circuit, D7 short in 20 seconds, then circuit protected. Power
consumption 1 - 40W. No high temperature, no hazard.
Monitored point: winding of TR1
consumption 1 - 40W. No high temperature, no hazard.
Monitored point: winding of TR1
59 130
D8 short circuit, as normal, no high temperature, no hazard. Monitored point:
winding of TR1
winding of TR1
51 130
EC12 short circuit, power consumption 1.2W, circuit protected. No high
temperature, no hazard.
temperature, no hazard.
- -
D9 short circuit, power consumption 3.1W, circuit protected. No high temperature,
no hazard.
no hazard.
- -
EC13 short circuit, D9 short in 20 seconds, then circuit protected. Power
consumption <3W. No high temperature, no hazard.
consumption <3W. No high temperature, no hazard.
- -
One speaker short, power consumption 22W, circuit protected.
Monitored point: winding of TR1
Monitored point: winding of TR1
50 130
Ventilating holes on side enclosure covered, no high temperature, no hazard.
Monitored point: winding of TR1
Monitored point: winding of TR1
54 130
Maximum volume on all loudspeakers, power consumption 133W, circuit
protected in 10s, the power consumption down to 66W, no high temperature, no
hazard.
protected in 10s, the power consumption down to 66W, no high temperature, no
hazard.
- -
Adjust volume on all loudspeakers, and circuit no protected, power consumption
max 73W, 2 hours, no high temperature, no hazard.
Monitored point: winding of LF2
max 73W, 2 hours, no high temperature, no hazard.
Monitored point: winding of LF2
89.5
130
R0 open circuit, the voltage between the pins of mains plug is less than 10V at 2s
after withdrawal of mains plug.
after withdrawal of mains plug.
- -