Ref. No. : JSH05090075-001 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065D 
 
     TRF originator BEAB 
D6 short circuit, power consumption <2.5W, circuit protected. No high 
temperature, no hazard. 
- - 
EC5 short circuit, power consumption <1W, circuit protected. No high 
temperature, no hazard. 
- - 
D7 short circuit, power consumption 37W, no audio output on speaker. No high 
temperature, no hazard. Monitored point: winding of TR1 
55 130 
EC7 short circuit, D7 short in 20 seconds, then circuit protected. Power 
consumption 1 - 40W. No high temperature, no hazard.                                  
Monitored point: winding of TR1 
59 130 
D8 short circuit, as normal, no high temperature, no hazard. Monitored point: 
winding of TR1 
51 130 
EC12 short circuit, power consumption 1.2W, circuit protected. No high 
temperature, no hazard. 
- - 
D9 short circuit, power consumption 3.1W, circuit protected. No high temperature, 
no hazard. 
- - 
EC13 short circuit, D9 short in 20 seconds, then circuit protected. Power 
consumption <3W. No high temperature, no hazard. 
- - 
One speaker short, power consumption 22W, circuit protected.                
Monitored point: winding of TR1 
50 130 
Ventilating holes on side enclosure covered, no high temperature, no hazard. 
Monitored point: winding of TR1 
54 130 
Maximum volume on all loudspeakers, power consumption 133W, circuit 
protected in 10s, the power consumption down to 66W, no high temperature, no 
hazard. 
- - 
Adjust volume on all loudspeakers, and circuit no protected, power consumption 
max 73W, 2 hours, no high temperature, no hazard.                                        
Monitored point: winding of LF2 
 
89.5 
 
130 
R0 open circuit, the voltage between the pins of mains plug is less than 10V at 2s 
after withdrawal of mains plug. 
- - 
      
Winding temperature rise measurements 
N/A 
      
Ambient temperature t1 (
o
C) .................................. :       
— 
      
Ambient temperature t2 (
o
C) .................................. :       
— 
 
 
 
 
 
 
 
 
 
 
 
Page of 52