Ref.No.: 609280
IEC 60065
Cl.
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
P
14.5.2.3
Not possible to connect fuses in parallel ............... : No
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
Tools are required
P
14.5.3
PTC-S thermistors comply with IEC 60738
N/A
PTC-S devices (15 W) category FV 1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
(See appended table)
14.6.1
Permanently connected equipment provided with
an all-pole mains switch unless 5.4.2 is met
an all-pole mains switch unless 5.4.2 is met
N/A
14.6.2
Manually operated mechanical switch (MOMS),
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
Yes
P
Switch readily accessible and not in mains cord
P
Exception for automatic switching
N/A
Exception for continuous operation
N/A
14.6.3
Manually operated mechanical switch (MOMS):
switch indication On position clearly discernible
switch indication On position clearly discernible
P
Indication by marking meets Cl. 5
P
Indication of the OFF position
P
14.6.4
Manually operated mechanical switch (MOMS)
fitted, is there a Stand-by mode ............................. :
fitted, is there a Stand-by mode ............................. :
N/A
Stand-by mode clearly discernible ......................... :
N/A
Exception for low Stand-by current < 0.7 mA
(peak)
(peak)
N/A
14.6.5
Components bridging contacts of mains switches
comply with 14.1 a) or 14.2.2
comply with 14.1 a) or 14.2.2
N/A