Read Harman Kardon HK 990 (serv.man4) EMC - CB Certificate online
Page 50 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
18
18.1A
Mechanical strength of picture tubes and protection
against the effects of implosion
against the effects of implosion
[Add the following clause]
A picture tube with a maximum face dimension exceeding 75
mm either shall be intrinsically protected with respect to
effects of implosion and to mechanical impact, in accordance
with CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965, or the
enclosure of the apparatus shall provide adequate protection
against the effects of an implosion of the tube (see Clause
12).
A picture tube with a maximum face dimension exceeding 75
mm either shall be intrinsically protected with respect to
effects of implosion and to mechanical impact, in accordance
with CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965, or the
enclosure of the apparatus shall provide adequate protection
against the effects of an implosion of the tube (see Clause
12).
N/A
19
Stability and mechanical hazards
[Add the following after the second paragraph]
The test of Clause 19.3 is only required for
a) apparatus with a mass of 25 kg or more;
b) apparatus, excluding loudspeaker systems, with a height of
1 m or more; or
c) apparatus, including loudspeaker systems, in combination
with a supplied or recommended cart or stand with a total
height of 1 m or more.
[Add the following paragraph]
Apparatus not tested because it is intended to be fastened in
place shall be provided with the following warning, marked on
the apparatus or on a durable label attached to the mains
cord:
“WARNING: This apparatus must be securely attached to the
floor/wall per installation instructions. Tipping, shaking, or
rocking the machine may cause injury/death.”
[Add the following after the second paragraph]
The test of Clause 19.3 is only required for
a) apparatus with a mass of 25 kg or more;
b) apparatus, excluding loudspeaker systems, with a height of
1 m or more; or
c) apparatus, including loudspeaker systems, in combination
with a supplied or recommended cart or stand with a total
height of 1 m or more.
[Add the following paragraph]
Apparatus not tested because it is intended to be fastened in
place shall be provided with the following warning, marked on
the apparatus or on a durable label attached to the mains
cord:
“WARNING: This apparatus must be securely attached to the
floor/wall per installation instructions. Tipping, shaking, or
rocking the machine may cause injury/death.”
N/A
20.2
20.2.1A
Fire enclosure
[Add the following clause]
Enclosures of apparatus containing high-voltage or projection
lamps shall have a minimum flammability rating of category
FV 1according to IEC 60707 at the minimum thickness used.
Enclosures of apparatus containing high-voltage or projection
lamps shall have a minimum flammability rating of category
FV 1according to IEC 60707 at the minimum thickness used.
N/A
Annex B
(normative)
(normative)
Replace this annex with the following]
Apparatus intended for direct connection to a
telecommunication network shall comply with
a) Clause 19 of CSA C22.2 No. 1; or
b) CAN/CSA-C22.2 No. 60950.
Apparatus intended for direct connection to a
telecommunication network shall comply with
a) Clause 19 of CSA C22.2 No. 1; or
b) CAN/CSA-C22.2 No. 60950.
N/A