Read Harman Kardon HK 990 (serv.man4) EMC - CB Certificate online
Page 45 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
12
12.3A
12.3A.1
12.3A.2
12.3A.2
Mechanical strength
Television impacts
[Add the following clause]
For television sets and similar apparatus using a cathode ray
tube larger than 160 mm diagonally, the top, sides, front, and
rear of the enclosure, including the safety screen where
provided, shall be capable of withstanding a single impact of 7
J in accordance with
Clause 12.3A.2 without developing any opening larger than
130 mm in the enclosure of the cathode ray tube, unless the
minor dimension of 2 any opening is not more than 7 mm.
When applied to a safety screen, the impact shall not result in
damage to its mounting to the extent that it is mechanically
unsuitable for reuse, nor shall tempered glass, if used, be
cracked.
When applied to the face of a directly viewed cathode ray
tube, the impact shall not cause any opening in the face of the
tube.
Scaling and cracking of the glass shall be permissible. A
cathode ray tube that has been shown to comply with
CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965 shall be
considered acceptable with no further tests.
The impact specified in Clause 12.3A.1 shall be caused by
allowing a solid, smooth, steel sphere 51 mm in diameter and
weighing approximately 0.5 kg to strike the enclosure with the
specified impact in a direction perpendicular to the enclosure
surface. If
deemed necessary, the enclosure shall be tested with the
proper cathode ray tube mounted.
For television sets and similar apparatus using a cathode ray
tube larger than 160 mm diagonally, the top, sides, front, and
rear of the enclosure, including the safety screen where
provided, shall be capable of withstanding a single impact of 7
J in accordance with
Clause 12.3A.2 without developing any opening larger than
130 mm in the enclosure of the cathode ray tube, unless the
minor dimension of 2 any opening is not more than 7 mm.
When applied to a safety screen, the impact shall not result in
damage to its mounting to the extent that it is mechanically
unsuitable for reuse, nor shall tempered glass, if used, be
cracked.
When applied to the face of a directly viewed cathode ray
tube, the impact shall not cause any opening in the face of the
tube.
Scaling and cracking of the glass shall be permissible. A
cathode ray tube that has been shown to comply with
CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965 shall be
considered acceptable with no further tests.
The impact specified in Clause 12.3A.1 shall be caused by
allowing a solid, smooth, steel sphere 51 mm in diameter and
weighing approximately 0.5 kg to strike the enclosure with the
specified impact in a direction perpendicular to the enclosure
surface. If
deemed necessary, the enclosure shall be tested with the
proper cathode ray tube mounted.
N/A
13.3
13.3.1
Clearances
General
[Add the following after the third paragraph]
Clearances between a loudspeaker voice coil and adjacent
conductive parts shall be disregarded.
[Add the following after the third paragraph]
Clearances between a loudspeaker voice coil and adjacent
conductive parts shall be disregarded.
N/A
14.2
14.2.1
14.2.2
Capacitors and RC-units
[Add the following paragraph]
As an alternative, an isolating capacitor complying with the
applicable requirements of CSA C22.2 No. 1 shall be
acceptable for bridging basic or supplementary insulation.
As an alternative, an isolating capacitor complying with the
applicable requirements of CSA C22.2 No. 1 shall be
acceptable for bridging basic or supplementary insulation.
[Add the following paragraph]
As an alternative, an across-line capacitor complying with the
applicable requirements of CSA C22.2 No. 1 shall be
acceptable.
As an alternative, an across-line capacitor complying with the
applicable requirements of CSA C22.2 No. 1 shall be
acceptable.
P
14.5.1
14.5.1.2
Thermal releases
[Add the following paragraph]
As an alternative, a thermal link complying with CSA C22.2
No. 209 shall be acceptable.
As an alternative, a thermal link complying with CSA C22.2
No. 209 shall be acceptable.
P
Click on the first or last page to see other HK 990 (serv.man4) service manuals if exist.