Read Harman Kardon HK 970 (serv.man14) EMC - CB Certificate online
INTERTEK TESTING SERVICES
12 of 19
Applicant: Harman Consumer Group
Report No.: 04173782
Model: HK 970
Test Summary
Pursuant to EN55020 (EN61000-4-3): RF EM field (Keyed Carrier)
Port: Enclosure
Basic Standard:
EN61000-4-3
Required Performance Criterion:
A
Limit: 3.0
V/m
(rms)
Test Modulation:
Duty Cycle 1/8, 217Hz Repetition
Frequency
Frequency: 895MHz
to
905MHz
Antenna Polarization:
Horizontal and Vertical
Dwell Time:
3s
Frequency Step
5MHz
Temperature: 25
°C
Relative Humidity:
43%
Test Facility:
Full Anechoic Chamber
Type of Antenna:
Log-periodic
Test Distance:
3 meters
Test Mode:
Amplifying
Test Setup:
Table-top
Size of The EUT:
L: 44 (cm)
× W: 36 (cm) × H: 10 (cm)
Used Test Equipment
Equipment
Registration No. Manufacturer Model No.
Serial No.
Signal Generator
EW-0423
IFR 2023B
202301/429
Log Periodic
Antenna
Antenna
EW-0572
EMCO 3146 9504-4038
RF Power
Amplifier
Amplifier
EW-0573
AMP
Research
Research
25W1000 15817
Audio Analyzer
(20Hz to 100kHz)
(20Hz to 100kHz)
EW-1815
PANASONIC VP-7723B
301837E12
5P
5P
Ctrl. No.: 13.1
Click on the first or last page to see other HK 970 (serv.man14) service manuals if exist.