HK 970 (serv.man14) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 21

Read Harman Kardon HK 970 (serv.man14) EMC - CB Certificate online

INTERTEK TESTING SERVICES 
 
12 of 19
 
Applicant: Harman Consumer Group 
Report No.: 04173782 
Model:  HK 970 
 
Test Summary 
Pursuant to EN55020 (EN61000-4-3): RF EM field (Keyed Carrier) 
 
Port: Enclosure 
Basic Standard: 
EN61000-4-3 
Required Performance Criterion: 
Limit: 3.0 
V/m 
(rms) 
Test Modulation: 
Duty Cycle 1/8, 217Hz Repetition 
Frequency 
Frequency: 895MHz 
to 
905MHz 
Antenna Polarization: 
Horizontal and Vertical 
Dwell Time:  
3s 
Frequency Step 
5MHz 
Temperature: 25
°C 
Relative Humidity: 
43% 
Test Facility: 
Full Anechoic Chamber 
Type of Antenna:  
Log-periodic 
Test Distance: 
 
3 meters 
Test Mode: 
Amplifying 
Test Setup: 
Table-top 
Size of The EUT: 
L: 44 (cm) 
× W: 36 (cm) × H: 10 (cm) 
 
Used Test Equipment 
 
Equipment  
Registration No.  Manufacturer  Model No. 
Serial No. 
Signal Generator 
EW-0423 
IFR 2023B 
202301/429
Log Periodic 
Antenna 
EW-0572 
EMCO 3146  9504-4038 
RF Power 
Amplifier 
EW-0573 
AMP 
Research 
25W1000 15817 
Audio Analyzer 
(20Hz to 100kHz) 
EW-1815 
PANASONIC VP-7723B 
301837E12
5P 
 
 
 
 
Ctrl. No.: 13.1 
Page of 33