Read Harman Kardon HK 970 (serv.man14) EMC - CB Certificate online
INTERTEK TESTING SERVICES
9 of 19
Applicant: Harman Consumer Group
Report No.: 04173782
Model: HK 970
Test Summary
Pursuant to EN55020 (EN61000-4-2): Electrostatic Discharge
Port: Enclosure
Basic Standard:
EN61000-4-2
Required Performance Criterion:
B
Limit:
±8.0 kV (Air Discharge)
±4.0 kV (Contact Discharge)
±4.0 kV (Indirect Contact Discharge)
Test Mode:
Amplifying
Test Setup:
Table-top
Test of Post-Installation:
N/A
Time Between Each Discharge:
1 second
Used Test Equipment
Equipment
Registration No. Manufacturer Model No.
Serial No.
Best EMC Test
Instrument
Instrument
EW-1214
Schaffner Best-EMC-1
200030-
0101SC
0101SC
Ctrl. No.: 7.1