Report No 248607.
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Applicable to portable/wall socket-outlet and portable cable reel
20 Portable/wall
socket-outlet
and portable
cable reel
and portable
cable reel
a) If residual current device (RCD) is
incorporated, its tripping current must
be less than 30mA and operating
time must be less than 0.1 second
and testing to sub-clauses 9.9.2.1,
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
b) The shutters screening the current-
carrying socket contacts shall not be
opened by the insertion of any
corresponding SINGLE pin of the
plug into any current-carrying socket
aperture.
incorporated, its tripping current must
be less than 30mA and operating
time must be less than 0.1 second
and testing to sub-clauses 9.9.2.1,
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
b) The shutters screening the current-
carrying socket contacts shall not be
opened by the insertion of any
corresponding SINGLE pin of the
plug into any current-carrying socket
aperture.
No portable/wall socket-
outlet and portable cable
reel.
outlet and portable cable
reel.
N/A
21
Wall switched
socket-outlet
(2 x single
socket-outlet)
socket-outlet
(2 x single
socket-outlet)
Single socket-outlet with 2-gang
faceplate/frame must be fulfilled
with the test requirements as 2-gang
socket-outlet.
faceplate/frame must be fulfilled
with the test requirements as 2-gang
socket-outlet.
N/A
22
Remote
controlled
portable/wall
portable
socket-outlet
controlled
portable/wall
portable
socket-outlet
Remote controlled portable/wall
socket-outlet shall not be
allowed for registration.
socket-outlet shall not be
allowed for registration.
N/A
Applicable to roaster
23
Roaster
A metal ring (Appendix U) must be
provided to prevent the roaster from
falling off in case the glass bowl
shattered.
provided to prevent the roaster from
falling off in case the glass bowl
shattered.
No roaster
N/A
Applicable to Residual Current Circuit Breaker (RCCB)
33
RCCB
Registration of RCCB is limited to 30
mA sensitivity and the operating time
must be less than 0.1 second.
Electronic RCCB will not be accepted
for registration.
mA sensitivity and the operating time
must be less than 0.1 second.
Electronic RCCB will not be accepted
for registration.
No residual current circuit
breaker
breaker
N/A
Applicable to electric instantaneous and storage water heater
34 Instantaneous
electric water
heater and mains
pressure electric
storage water
heater
heater and mains
pressure electric
storage water
heater
Heating elements used must not
be of the "bare-element" type.
be of the "bare-element" type.
No electric instantaneous
and storage water heater
and storage water heater
N/A
35 Water
heater
incorporated with
residual current
device(RCD)
residual current
device(RCD)
Testing to sub-clauses 9.9.2.1,
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
N/A
Click on the first or last page to see other HK 3770 (serv.man2) service manuals if exist.