Report No 248607.
 
ATTACHMENT 4 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065K 
 
13.3.1 
 
NO: To the second paragraph the following is 
added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
Considered to IT power 
distribution system.
 
15.1.1 
(A11:2008) 
 
Denmark  
The text of the Danish SNC in EN 60065:2002 has 
been modified as follows:  
To the first paragraph the following is added:  
In Denmark, supply cords of single-phase 
appliances having a rated current not exceeding 13 
A shall be provided with a plug according to the 
Heavy Current Regulations Section 107-2-D1.  
Appliances of CLASS I provided with socket-outlets 
with earth contact or which are intended to be used 
in locations where protection against indirect 
contact is required according to the wiring rules 
shall be provided with a plug in accordance with the 
Heavy Current Regulations, Section 107-2-D1 
standard sheet DK 2-1a.  
To the second paragraph the following is added:  
Socket outlets intended for providing power to 
CLASS II apparatus with a rated current of 2,5 A 
shall be in accordance with the Heavy Current 
Regulation, Section 107-2-D1 standard sheet DKA 
1-4a.  
Other current ratings socket outlets shall be in 
compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DKA 1-3a or DKA 
1-3b.  
To the third paragraph the following is added:  
Mains socket-outlets with earthing contact shall be 
in compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a 
or DK 1-7a.  
Justification: Heavy Current Regulations, Section 
107-2-D1 
No socket outlets. 
N/A 
15.1.1 
IE: Apparatus which is fitted with a flexible cable or 
cord shall be provided with a 13 A plug in 
accordance with Statutory Instrument 525:97, “13 A  
Plugs and Conversion Adapters for Domestic Use 
Regulations:1997. 
Justification: SI 525: 1997 
Not provided. 
See summary of testing. 
N/A 