Read Harman Kardon HK 3700 (serv.man4) EMC - CB Certificate online
Page 13 of 15
Report No 248608.
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13.3.1
NO: To the second paragraph the following is
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
Considered to IT power
distribution system.
distribution system.
P
15.1.1
(A11:2008)
(A11:2008)
Denmark
The text of the Danish SNC in EN 60065:2002 has
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DKA
1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
The text of the Danish SNC in EN 60065:2002 has
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DKA
1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
No socket outlets.
N/A
15.1.1
IE: Apparatus which is fitted with a flexible cable or
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification: SI 525: 1997
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification: SI 525: 1997
Not provided.
See summary of testing.
See summary of testing.
N/A