HK 3700 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 17

Read Harman Kardon HK 3700 (serv.man4) EMC - CB Certificate online

  
Page 13 of 49
Report No 248608.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
P 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltage >1000 V ac or 
>1500 V dc 
N/A 
9.1.1.1 
a) Open circuit voltages  
Mains input voltage 
>35 V ac, see below. 
 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................ : 
U1: Max. 0.64 V (peak) 
U2: Max. 0.30 V (peak) 
(Tested at 264 V/ 60 Hz) 
P 
 
c) Discharge not exceeding 45 μC  
No part or contact of a 
terminal with stored voltages 
between 60 V – 150 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
No part or contact of a terminal 
with stored voltages exceeding 
15 kV. 
N/A 
9.1.1.2 
Test with test finger and test probe  
No access to hazardous 
live parts. 
P 
9.1.2 
No hazardous live shafts of knobs, handles or levers  No live shafts of knobs, 
handles or levers. 
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No access for the test pin. 
P 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Does not reach hazardous 
live parts. 
P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Does not reach hazardous 
live parts. 
P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set controls. 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
32 V dc after 2 s, 
Bleeder resistor provided. 
See clause 14.1 b), and 
appended table, list of critical 
components. 
P 
 
If C is not greater than 0,1 μF no test needed  
> 0.1 μF 
N/A 
9.1.7 
Resistance to external forces 
 
P 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
Test with test finger results 
in no hazard. 
P 
 
b) Test hook of fig. 4 for 10 s (20 N)  
Test with test hook results 
in no hazard. 
P 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
Tested 100 N result in no 
hazard. 
P 
9.2 
No hazard after removing a cover by hand  
No cover removable by hand 
N/A 
 
Page of 90
Display