Read Harman Kardon HK 3490 (serv.man2) EMC - CB Certificate online
- Page 40 of 45 -
Report
No.
98503
Monitored point:
Under fault conditions specified below - continued
Under fault conditions specified below - continued
dT (K)
Limit dT (K)
*), C309, S-c;
Left speaker output signal off immediately.
Input current stabilised at 1,03A. R353 damaged.
No hazard. (Tested time; 3.0 min)
Left speaker output signal off immediately.
Input current stabilised at 1,03A. R353 damaged.
No hazard. (Tested time; 3.0 min)
N/A N/A
*), Right speaker, S-c;
Right speaker output signal off immediately.
Input current stabilised at 1,15A. Q321, Q322 damaged.
No hazard. (Tested time; 30 min)
Right speaker output signal off immediately.
Input current stabilised at 1,15A. Q321, Q322 damaged.
No hazard. (Tested time; 30 min)
N/A N/A
*), Ventilation opening (Blocked);
Unit shut down after 8 min. Input current stabilised at 0,008A.
No component damaged. Dielectric strength test O.K.
No hazard. (Tested time: 16 min)
Unit shut down after 8 min. Input current stabilised at 0,008A.
No component damaged. Dielectric strength test O.K.
No hazard. (Tested time: 16 min)
N/A N/A
*), Pmax. Operating (Maximum non-clipped output signal);
1st.
Winding of main transformer heated up to 159K and thermal fuse opened
after 31 min. Input current stabilised at 0,008A. Dielectric strength test O.K.
No hazard. (Tested time: 31 min)
2nd.
Winding of main transformer heated up to 161K and thermal fuse opened
after 10 min. Input current stabilised at 0,008A. Dielectric strength test O.K.
No hazard. (Tested time: 10 min)
3rd.
Winding of main transformer heated up to 149K and thermal fuse opened
after 10 min. Input current stabilised at 0,008A. Dielectric strength test O.K.
No hazard. (Tested time: 10 min)
1st.
Winding of main transformer heated up to 159K and thermal fuse opened
after 31 min. Input current stabilised at 0,008A. Dielectric strength test O.K.
No hazard. (Tested time: 31 min)
2nd.
Winding of main transformer heated up to 161K and thermal fuse opened
after 10 min. Input current stabilised at 0,008A. Dielectric strength test O.K.
No hazard. (Tested time: 10 min)
3rd.
Winding of main transformer heated up to 149K and thermal fuse opened
after 10 min. Input current stabilised at 0,008A. Dielectric strength test O.K.
No hazard. (Tested time: 10 min)
Main transf.
See #) below
Main transf.
See #) below
Main transf.
149
Main transf.
150
Main transf.
150
Main transf.
150
*) Tested voltage 253V **) Tested voltage 198V
#) The temperature rise of the main transformer was measured to > 150K of allowable limit, but
transformer passed the testes described in sub clause 11.2.5 (tests repeated three times).
transformer passed the testes described in sub clause 11.2.5 (tests repeated three times).
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
Click on the first or last page to see other HK 3490 (serv.man2) service manuals if exist.