Read Harman Kardon HK 3490 (serv.man2) EMC - CB Certificate online
- Page 39 of 45 -
Report
No.
98503
Monitored point:
Under fault conditions specified below - continued
Under fault conditions specified below - continued
dT (K)
Limit dT (K)
*), C561, S-c;
Normal operated. Input current stabilised at 1,80A.
R999 damaged. No hazard. (Tested time; 10 min)
Normal operated. Input current stabilised at 1,80A.
R999 damaged. No hazard. (Tested time; 10 min)
N/A N/A
**), C561, S-c;
Normal operated. Input current stabilised at 1,69A.R999 damaged.
No hazard. (Tested time; 10 min)
Normal operated. Input current stabilised at 1,69A.R999 damaged.
No hazard. (Tested time; 10 min)
N/A N/A
*), D703 (A to C), S-c;
Normal operated. Input current stabilised at 1,80A. R998 damaged.
No hazard. (Tested time; 10 min)
Normal operated. Input current stabilised at 1,80A. R998 damaged.
No hazard. (Tested time; 10 min)
N/A N/A
*), C763, S-c;
Normal operated. Input current stabilised at 1,80A. R996 damaged.
No hazard. (Tested time; 30 min)
Normal operated. Input current stabilised at 1,80A. R996 damaged.
No hazard. (Tested time; 30 min)
N/A N/A
*), D704 (A to C), S-c;
Normal operated. Input current stabilised at 1,90A. R998 damaged.
No hazard. (Tested time; 30 min)
Normal operated. Input current stabilised at 1,90A. R998 damaged.
No hazard. (Tested time; 30 min)
N/A N/A
*), C112, S-c;
Sub transformer thermal fuse opened after 9 min.
Dielectric strength test OK. No hazard. (Tested time; 9 min)
Sub transformer thermal fuse opened after 9 min.
Dielectric strength test OK. No hazard. (Tested time; 9 min)
Sub transf.
102,8
Sub transf.
150
*), D110 (A to C), S-c;
Sub transformer thermal fuse opened after 10 min.
Dielectric strength test OK. No hazard. (Tested time; 10 min)
Sub transformer thermal fuse opened after 10 min.
Dielectric strength test OK. No hazard. (Tested time; 10 min)
Sub transf.
105
Sub transf.
150
*), Q319 (C to E), S-c;
Unit shut down immediately, except front display.
Input current stabilised at 0,25A. Q321, Q317 damaged. F603, F604 opened.
No hazard. (Tested time; 10 min)
Unit shut down immediately, except front display.
Input current stabilised at 0,25A. Q321, Q317 damaged. F603, F604 opened.
No hazard. (Tested time; 10 min)
N/A N/A
*), Q319 (C to B), S-c;
Unit shut down immediately. Input current stabilised at 0,01A.
Q321, Q319, Q317 damaged. R347 damaged.
No hazard. (Tested time; 10 min)
Unit shut down immediately. Input current stabilised at 0,01A.
Q321, Q319, Q317 damaged. R347 damaged.
No hazard. (Tested time; 10 min)
N/A N/A
**), Q321 (C to E), S-c;
Unit shut down immediately. Input current stabilised at 0,01A.
Q321 damaged. F603, F604 opened. No hazard. (Tested time; 10 min)
Unit shut down immediately. Input current stabilised at 0,01A.
Q321 damaged. F603, F604 opened. No hazard. (Tested time; 10 min)
N/A N/A
**), Q321 (C to B), S-c;
Unit shut down after 2 sec. Input current stabilised at 0,01A.
Q319, Q317, R347 damaged. F603, F604 opened.
No hazard. (Tested time; 10 min)
Unit shut down after 2 sec. Input current stabilised at 0,01A.
Q319, Q317, R347 damaged. F603, F604 opened.
No hazard. (Tested time; 10 min)
N/A N/A
**), C307, S-c;
Left speaker output voltage dropped (at 2,34V) immediately.
Input current stabilised at 1,08A. Q319, R351 damaged.
No hazard. (Tested time; 30 min)
Left speaker output voltage dropped (at 2,34V) immediately.
Input current stabilised at 1,08A. Q319, R351 damaged.
No hazard. (Tested time; 30 min)
N/A N/A
*) Tested voltage 253V **) Tested voltage 198V
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded