HK 3480 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 22

Read Harman Kardon HK 3480 (serv.man2) EMC - CB Certificate online

 
 
- Page 17 of 32 - 
 
 
www.nemko.com
 
Report No.  65743 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.6.1 b) 
Tested in the apparatus: 
 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
Separately approved relay. 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
Separately approved relay. 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
Separately approved relay. 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1 
Apparatus surge : 22A 
Socket outlet surge  : 20A 
Total surge : 42A 
 
The measured surge current 
value is less than rated surge 
current rating of the mains 
relay. OK. 
 
Socket outlet current marking correct 
Socket outlet marking: 
SWITCHED, 50W MAX, 0.25A
 
14.7 Safety 
interlocks 
No safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
14.8 
Voltage setting devices 
No voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 
14.9 Motors 
No motors 
14.9.1 
Endurance test on motors 
 
 
Motor start test 
 
 
Dielectric strength test 
 
TRF No:  IEC/EN 60065F 
Page of 48