Report No. 65743
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved relay.
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved relay.
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved relay.
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
Apparatus surge : 22A
Socket outlet surge : 20A
Total surge : 42A
The measured surge current
value is less than rated surge
current rating of the mains
relay. OK.
Socket outlet surge : 20A
Total surge : 42A
The measured surge current
value is less than rated surge
current rating of the mains
relay. OK.
P
Socket outlet current marking correct
Socket outlet marking:
SWITCHED, 50W MAX, 0.25A
P
14.7 Safety
interlocks
No safety interlocks
N
Safety interlocks to 2.8 of IEC 60950
N
14.8
Voltage setting devices
No voltage setting devices
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9 Motors
No motors
N
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
TRF No: IEC/EN 60065F