Read Harman Kardon HK 3480 (serv.man2) EMC - CB Certificate online
- Page 16 of 32 -
www.nemko.com
Report No. 65743
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.5.1.1
a) Thermal cut-outs separately approved
None
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
The thermal link in main
transformer, separately
approved, see appended table,
list of critical components.
transformer, separately
approved, see appended table,
list of critical components.
P
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No such thermal device
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are certified according
to IEC60127
to IEC60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Correct marking applied close
to the fuse;
F601: T6.3A L 250V,
F602: T2.5A L 250V,
F603, F604: T8A L 250V
to the fuse;
F601: T6.3A L 250V,
F602: T2.5A L 250V,
F603, F604: T8A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
No fuse holder so designed that
fuse-links can be connected in
parallel
fuse-links can be connected in
parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
None
N
PTC-S devices (15 W) category V-1 or better
None
N
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
Secondary F603, and F604
fuses have adequately
breaking capacity. Fault
condition repeated three times
where one of the above fuse
opened.
fuses have adequately
breaking capacity. Fault
condition repeated three times
where one of the above fuse
opened.
P
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
No mains switch, but mains
relay provided and certified
according to IEC61058-1 by
SEMKO.
See appended table, list of
critical components.
relay provided and certified
according to IEC61058-1 by
SEMKO.
See appended table, list of
critical components.
P
TRF No: IEC/EN 60065F
Click on the first or last page to see other HK 3480 (serv.man2) service manuals if exist.