STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ............. :
Weight: 9,7 kg
⎯
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
No
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
Tested on a plane inclined
at an angle of 10°
at an angle of 10°
P
19.2
100 N force applied vertically downwards
100N force have no
influence on the stability
influence on the stability
P
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
to point of least stability.
< 25 kg, < 1M
N/A
19.4
Edges or corners not hazardous
There is no hazardous
edges or corners when the
apparatus is operating in
normal position
edges or corners when the
apparatus is operating in
normal position
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
No glass surface.
N/A
19.6
Wall or ceiling mountings adequate
No wall or ceiling
mountings.
mountings.
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC
enclosure of material V-0 to IEC
60695-11-10
with
openings not exceeding 1 mm in width
.
N/A
b) Exemption for small components as defined in
20.1
20.1
PCB are of flammability
class V-0 and exception is
made for small components
class V-0 and exception is
made for small components
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components
comply with flammability
requirements in clause 14.
comply with flammability
requirements in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure,
> 4 Kv or leaving an internal fire enclosure,
or
located within the areas mentioned in Table 21,
not contributing to the spread of fire
No wires working at
voltages > 4kV or leaving
an internal fire enclosure
voltages > 4kV or leaving
an internal fire enclosure
N/A