Read Harman Kardon HK 3390 EMC - CB Certificate online
- Page 25 of 43 -
Report
No.
98502
16.5
Adequate strain relief on external flexible cords
Cord clip wedged in the
enclosure
enclosure
P
Not possible to push cord back into equipment
Checked by inspection
P
Strain relief device unlikely to damage flexible
cord
cord
No sharp edges
P
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
Class II apparatus.
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
No sharp edges
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
The apparatus is not a
transportable musical
instrument and amplifier
transportable musical
instrument and amplifier
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
The apparatus is not a
transportable musical
instrument and amplifier
transportable musical
instrument and amplifier
N/A
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
Screws fixing chassis to the
main enclosure tested.
main enclosure tested.
P
- screws into metal: 5 times
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
- screws into non-metallic material: 10 times
N/A
17.2
Correct introduction into female threads in non-
metallic material
metallic material
No female threads in
non-metallic materials
non-metallic materials
N/A
17.3
Cover fixing screws: captive
Captivity not necessary
P
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
Tested with screw with
10 times diameter.
10 times diameter.
P
17.4
No loosening of conductive parts carrying a
current > 0,2 A
current > 0,2 A
Loosening is sufficiently
prevented
prevented
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
No contact pressure
transmitted through
insulating material.
transmitted through
insulating material.
P