Read Harman Kardon HK 3390 (serv.man3) EMC - CB Certificate online
- Page 8 of 13 -
Report
No.
132229
7.1
TABLE: temperature rise measurements
P
Monitored point:
dT (K) at
198V, 60Hz
dT (K) at
242V, 60Hz
Limit dT (K)
Sub transformer core
27.3
32.1
85
PWB near D109
21.7
25.2
95
E-capacitor, C112 body
20.4
24.7
85
°C
Ambient
21.6
o
C 22.6
o
C -
Winding temperature rise
measurements
measurements
198V,
60Hz
242V,
60Hz
—
Ambient temperature t1 (
o
C) :
22.0
22.0
—
Ambient temperature t2 (
o
C) :
21.6
22.6
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K) Insulation
class
Sub transf. Pri. winding (198V, 60Hz)
3442
3815
28.2
85
E
Sub transf. Pri. winding (242V, 60Hz)
3442
3910
34.3
85
E
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
Min 2
Between parts separated by double or reinforced insulation
> 100
Min 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500Vac
No
Between parts separated by double or reinforced insulation
3000Vac No
Click on the first or last page to see other HK 3390 (serv.man3) service manuals if exist.