132229
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by position of
the functional switch (W)
the functional switch (W)
Less than 0.90W
(at rated 230V mains)
(at rated 230V mains)
—
Operating conditions
Standby mode at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
220 0.007 0.81 —
230 0.007 0.90 —
Standby mode at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
220 0.007 0.73 —
230 0.008 0.78 —
Measured at maximum non-clipped output at 50Hz:
Un (V)
In (A)
Pn (W)
Pout (W)
253
2.84
614.8
2 x 74.5 W
(SPK 1)
2 x 74.1 W
(SPK 2)
Measured at maximum non-clipped output at 60Hz:
Un (V)
In (A)
Pn (W)
Pout (W)
253
2.80
609.6
2 x 74.5 W
(SPK 1)
2 x 74.1 W
(SPK 2)
Measured condition; 1kHz input signal, connected 8 ohm loads for Speaker 1 and Speaker 2 channels