Read Harman Kardon HK 3390 (serv.man2) EMC - CB Certificate online
Anam Electronics Co., Ltd.
Page 11 of 17
HK3390/230
EMC Test Report
Reference No.:NK08E066
7. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test
7.1 Test Procedure
The tests were performed at 3 m distance in an anechoic chamber.
For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor.
The EUT was exposed to the field from different angles, normally 0º, 90º, 180º, 270º and at both horizontal
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor.
The EUT was exposed to the field from different angles, normally 0º, 90º, 180º, 270º and at both horizontal
and vertical polarization(antenna height 1.75 m)
A signal level of 3 V / m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was
detected using microphone and selected level meter
detected using microphone and selected level meter
Instrumentation used during this session:
Instruments Manufacturer
Model
Serial number
Due to Calibration
Signal Generator
R & S
SMY01
830766/032
2008.03
Function Generator
Agilent Tech
33120A
US36042890
2008.12
Power Amplifier
Noiseken
NA25MF1G2010C
A00518
2008.10
Power Sensor
HP
8482A
US37293322
2008.03
Power Sensor
HP
8482A
US37293323
2008.03
Power Meter
HP
E4419B
GB39511164
2008.03
Biconical log
Antenna
Antenna
ARA LPB-2520/A
1180 2008.02
Position Controller
Seo-Young EMC
N/A
N/A
N/A
Turntable Seo-Young
EMC
N/A
N/A N/A
7.2 Test Parameters
Port:
Enclosure
Basic Standard:
EN 61000-4-3:2002+A1:2002
Performance Criteria: A
Performance Results :
A
Test Engineer:
Jin-ha, Ko
Dwell Time:
120 s
Modulation:
Duty Cycle 1/8 PM @ 217 Hz
Frequency Range:
900 MHz
Test Level:
3 V / m
Click on the first or last page to see other HK 3390 (serv.man2) service manuals if exist.