HK3390/230 
EMC Test Report
 
         
Reference No.:NK08E066 
4. Evaluation Of Performance 
 
4.1 Performance Criteria 
 
      Criteria A 
The equipment shall continue to operate as intended during the test. 
No change of actual operating state is allowed as result of the application of the test. 
Multifunction equipment shall for each function meet the relevant requirements. 
Evaluation is carried out for audio and video functions. 
1) Evaluation of audio quality 
The criterion of compliance with the requirement is a wanted to unwanted audio signal ratio of  ≥40dB  
at a wanted audio signal level of 500mV, or at another audio signal level specified by the manufacturer. 
2) Evaluation of picture quality 
In the evaluation of picture interference the wanted test signal produces a standard picture and the 
unwanted signal produces a degradation of picture. The degradation may be in a number of forms,   
such as a superposed pattern, disturbance of synchronization, geometrical distortion, loss of picture   
contrast, of color. 
The criterion of compliance with the requirement is just perceptible degradation by observation of 
the picture. The screen shall be observed under normal viewing conditions (brightness 15 lx to 20 lx), 
at a viewing distance of six times the height of the screen. 
 
      Criteria B 
The device shall continue to operate as intended after the test. No loss of function is allowed after   
the test when the apparatus is used as intended, but failures which are recovered automatically   
but which cause temporary delay in processing, are permissible. No change of actual operating   
state for example change of channel or stored data and settings is allowed as a result of the application 
of the test. During the test, degradation of performance is allowed.   
 
4.2 Measurement Uncertainty 
 
   Measurement uncertainty is calibrated in accordance with: 
      ●EMCIT document 93/30 
      ●NAMAS Information Sheet NIS81, Ed.1 May 1994 
(The treatment of uncertainties in EMC measurement). 
      The measurement uncertainty is not considered when deciding PASS or FAIL against the limit lines. 
      This means that “shared risk” (according to NAMAS publication NIS81 4.2) is used as option   
      Criterion. The argument for using this method, is that it is commonly accepted that the EMC limits   
      have already taken common good laboratory practice. 
 
4.3 Final Decision 
       
      The equipment under test complies to all requirements of the applied test standards.     
     