GO PLAY WIRELESS (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 7

Read Harman Kardon GO PLAY WIRELESS (serv.man4) EMC - CB Certificate online

Report No.: EM201200637-2                     Application No.: ZJ00022731                    Page 7 of 18 
 
 
3. TECHNICAL REQUIREMENTS SPECIFICATION IN EN 62311 
3.1 GENERAL DESCRIPTION OF APPLIED STANDARDS 
EN 62311 Generic standard to demonstrate the compliance of electronic and electrical 
apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 
Hz–300 GHz) is to demonstrate the compliance of apparatus with the basic restrictions or 
reference levels on exposure of the general public related to electric, magnetic, 
electromagnetic fields as well as induced and contact current. 
 
3.2 RF EXPOSURE EVALUATION 
3.2.1 LIMIT: 
According to EN 62311, If the average power emitted by the base station is less than or 
equal to 20 mW then the base station is deemed to comply without testing. 
If the average power emitted by the base station is less than or equal to 20 mW then the 
base station is deemed to comply without testing. 
If the average power emitted by the base station is more than 20 mW, then E, H or SAR 
calculations and/or measurements shall be performed according to Clause 4. The results 
of 
calculations and/or measurements shall be compared directly to the limits. 
The product is deemed to fulfil the requirements of this standard if the calculated and/or 
measured 
values are less than or equal to the limits. 
NOTE In the setting of basic restrictions and the derived reference levels, safety factors 
have been taken into account. In the specification of the assessment method, uncertainty 
has been constrained. This is the reason for not requiring that the measured values shall 
be compared to the limit reduced by the measurement uncertainty. 
Test conclusion: 
MPE calculate procedure: 
According to the formula S = 
2
R
PG
π
  
Where: S = power density (in appropriate units, e.g. mW/cm
2
 
P = power input to the antenna (in appropriate units, e.g., mW) 
 
G = power gain of the antenna in the direction of interest relative to an isotropic  
radiator. 
 
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) 
And the limit of table 2 of Council Recommendation 1999/519/EC 
Page of 18
Display

Click on the first or last page to see other GO PLAY WIRELESS (serv.man4) service manuals if exist.