Power Source:
TX-43/51P250, TC-51P250H: AC 220V-240V, 50/60Hz
TX-43/51P250X: AC 110V-240V, 50/60Hz
Power Consumption:
TX-43/51P250, TC-51P250H: 228W
TX-43/51P250X: 238W
3.0W (Stand-by condition)
Aerial Impedance:
75
9
unbalanced, Coaxial type
Tuning System:
21 Systems
Frequency Synthesizer
Auto Search
100(Position)/125(Direct)
Receiving Channels:
2-12
(PAL/ SECAM - B, K1)
0-12
(PAL-B AUST.)
1-9
(PAL-B N.Z.)
1-12
(PAL/SECAM-D)
1-12
(NTSC-M JAPAN)
2-13
(NTSC-M U.S.A.)
21-69
(PAL-G, H, I)
21-69
(SECAM-G, K, K1)
28-69
(PAL-B AUST.)
13-57
(PAL-D, K)
13-62
(NTSC-M Japan)
14-69
(NTSC-M U.S.A.)
CATV
S1-S20
(OSCAR)
TX-43P250
TX-51P250
TC-43P250
TC-51P250
EURO-7VPChassis
S21-S41
(HYPER)
1-125
(U.S.A. CATV)
5A, 9A
(AUST.)
Z1-Z37
(CHINA)
C13-C49
(JAPAN)
Intermediate Frequency:
Video
38.0 MHz
Sound
31.5 MHz (D, K)/32.0 MHz (I)
32.5 MHz (B, G)/33.5 MHz (M)
Colour
33.57 MHz (PAL)/33.6 MHz (SECAM)
33.75 MHz (SECAM)/34.42 MHz (NTSC)
Receiving Stereo sound system:
NICAM B/G, NICAM I,
NICAM D, A2 (German)
Screen Size:
Type 51
Type 43
Diagonal:
296 mm
1092 mm
Height:
780 mm
655 mm
Width:
1037 mm
874 mm
Projection Tube:
Type 51
Type 43
TVVAB10GAV (B-ASSY)
TVVAB10GLV (B-ASSY)
TVVAG10GAV (G-ASSY)
TVVAG10GLV (G-ASSY)
TVVAR10GAV (R-ASSY)
TVVAR10GLV (R-ASSY)
90° deflection
High Voltage:
31.5 ± 1.0 kV at zero beam current
Audio Output:
Projection Television
Specifications
ORDER NO. ITD0110012C3
24 W [2-way, 4-speakers; 12 W+12 W] (10% THD)
Video/Audio Terminals:
AV1, 2, 3, 4 IN Video
1 Vp-p 75
9
S-Video
Y: 1.0 Vp-p 75
9
C: 0.3Vp-p 75
9
Audio
Approx. 0.4V 47k
9
Monitor OUT
Video
1Vp-p 75
9
Audio
Approx. 0.4V 1k
9
Dimensions:
Type 51
Type 43
Height:
1385 mm
1260 mm
Width:
1095 mm
932 mm
1 Safety Precautions
4
1.1. General Guide Lines
4
1.2. Leakage Current Cold Check
4
1.3. Leakage Current Hot Check (See Fig.1)
4
1.4. X-Radiation
4
2 Chassis Board Layout
5
3 Disassembly for Service
6
3.1. Disassembly Flowchart
6
3.2. Ornament Panel
7
3.3. Cabinet (Top)
7
3.4. Speaker Grille
7
3.5. Speaker Ass
y
7
3.6. Screen
8
3.7. Mirror
8
3.8. Rear Cover (Top)
8
3.9. Rear Cover (Bottom)
8
3.10. Disassembly For CRT Removal
9
4 Service Hints
10
4.1. Service position for Main chassis
10
4.2. Service Position for DG-Board
10
4.3. Service Position for M-Board
10
5 Self Check
11
6 Service Mode Function
12
6.1. How to enter SERVICE 1
12
6.2. How to enter SERVICE 2
12
6.3. Option Descrition
13
7 CRT Set Up
16
7.1. Dynamic Focus Adjustment
16
7.2. Electrical Focus Adjustment
16
7.3. Optical Lens Focus Adjustment
16
7.4. Centering Magnet Adjustment
17
7.5. Alignment magnet Adjustment
18
8 Deflection Adjustment
19
Depth:
500 mm
500 mm
Mass:
Type 51
Type 43
58 kg
54 kg
Accessories Supplied:
Remote Controller x 1
"R6" Battery x 2
75
9
coaxial aerial plug
Design and Specifications are subject to change without notice.
Mass and dimensions shown are approximate.
8.1. PAL 100Hz mode (100i)
19
8.2. PAL Progressive mode (50p)
20
8.3. NTSC Progressive mode (60p)
20
8.4. NTSC 120Hz mode (120i)
21
8.5. 525p Deflection Adjustment / Confirmation
22
8.6. 625p Deflection Adjustment / Confirmation
22
9 Adjustment Procedure
23
9.1. SECAM Black Level Adjustment
23
9.2. Cut off Adjustment
24
9.3. Sub Contrast / G-Limit Adjustment
25
9.4. Sub Picture Contrast Adjustment
25
9.5. NTSC Tint Adjustment
26
9.6. Sub Color Adjustment
26
9.7. Blue Focus / Gamma Adjustment
27
9.8. White Balance Adjustment
27
9.9. Sub Bright Adjustment
28
9.10. Blue Limit Adjustment
28
10 Convergence Adjustment
29
10.1. Convergence Adjutment Sheet
29
10.2. Convergence Adjustment Procedure
31
10.3. Coarse Convergence Adjustment mode
32
10.4. Fine Convergence Adjustment
38
11 Location of Lead Wiring
42
11.1. Location of Lead Wiring (1)
42
11.2. Location of Lead Wiring (2)
44
12 Conductor Views
47
12.1. A-Board
47
12.2. D-Board
50
12.3. DG-Board
53
12.4. H-Board
54
12.5. LB-Board and LR-Board
55
12.6. LG-Board and M-Board
56
12.7. P-Board
57
CONTENTS
Page
Page
2
TX-43P250 / TX-51P250 / TC-43P250 / TC-51P250
12.8. U-Board
58
13 Block Diagram
59
13.1. Audio Block Diagram
59
13.2. Video Block Diagram
60
13.3. Power Block Diagram
62
13.4. Control Block Diagram
66
14 Schematic Diagram
67
14.1. Schematic Diagram Notes
67
14.2. A-Board (1/4) Schematic Diagram
68
14.3. A-Board (2/4) Schematic Diagram
69
14.4. A-Board (3/4) Schematic Diagram
70
14.5. A-Board (4/4) Schematic Diagram
71
14.6. D-Board (1/2) Schematic Diagram
72
14.7. D-Board (2/2) Schematic Diagram
73
14.8. DG-Board (1/2) Schematic Diagram
74
14.9. DG-Board (2/2) Schematic Diagram
75
14.10. H-Board Schematic Diagram
76
14.11. LG-Board Schematic Diagram
77
14.12. LB and LR-Board Schematic Diagram
78
14.13. M-Board Schematic Diagram
79
14.14. P-Board Schematic Diagram
80
14.15. U-Board Schematic Diagram
81
15 Parts Location
83
16 Mechanical Replacement Parts List
84
17 Electrical Replacement Parts List
86
17.1. Replacement Parts List Notes
86
17.2. Electrical Replacement Parts List
87
3
TX-43P250 / TX-51P250 / TC-43P250 / TC-51P250
1.1.
General Guide Lines
1. It is advisable to insert an isolation transformer in the AC
supply before servicing a hot chassis.
2. When servicing, observe the original lead dress, especially
the lead dress in the high voltage circuits.
If a short circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
3. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers, shields, and
isolation R-C combinations, are properly installed.
4. When the receiver is not to be used for a long period of
time, unplug the power cord from the AC outlet.
5. Potential, as high as 31.5kV, is present when this monitor is
in operation. Operation of the Projection Monitor without the
rear cover involves the danger of a shock hazard from the
power supply. Servicing should not be attempted by anyone
who is not thoroughly familiar with the precautions
necessary when working on high voltage equipment.
Always discharge the anode of the projection tube to the
Projection Monitor chassis before handling the tube.
6. After servicing make the following leakage current checks to
prevent the customer from being exposed to shock
hazards.
1.2.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Turn on the Projection Monitor´s power switch.
3. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the projection monitor, such as screw heads,
connectors, control shafts, etc. When the exposed metallic
part has a return path to the chassis, the reading should be
between 4 M
9
and 20 M
9
.
When the exposed metal does not have a return path to the
chassis, the reading must be
.
1.3.
Leakage Current Hot Check
(See Fig.1)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 2k
9
, 10W resistor, in series with an exposed
metallic part on the projection monitor and an earth such as
a water pipe.
3. Use an AC voltmeter, with high impedance type, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 1.0V rms. In
case a measurement is outside of the limits specified, there
is a possibility of a shock hazard, and the projection monitor
should be repaired and rechecked before it is returned to
the customer.
Fig. 1
1.4.
X-Radiation
Warning :
1. The potential sources of X-Radiation in projection
monitor are the High Voltage section and the projection
tube.
2. When using a projection tube test jig for service, ensure
that jig is capable of handling 31.5kV without causing X-
Radiation.
Note:
It is important use an accurate periodically calibrated high
voltage meter.
1. Set the brightness to minimum.
2. Set the service switch to the service position.
3. Measure the High Voltage. The meter reading should
indicate 31.5 ± 1.0 kV. If the meter indication is out of
tolerance, immediate service and correction is required to
prevent the possibility of premature component failure.
4. To prevent an X-Radiation possibility, it is essential to use
the specified projection tube.
1 Safety Precautions
4
TX-43P250 / TX-51P250 / TC-43P250 / TC-51P250
Page of 101
Display

Download Panasonic TX-43P250 / TX-51P250 / TC-43P250 / TC-51P250 Service Manual (Repair Manual)

Here you can read online and download Panasonic TX-43P250 / TX-51P250 / TC-43P250 / TC-51P250 Service Manual in PDF. TX-43P250 / TX-51P250 / TC-43P250 / TC-51P250 service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic TX-43P250 / TX-51P250 / TC-43P250 / TC-51P250 TV. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.