Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
P
5.1.1 General
P
5.1.2
Equipment under test (EUT)
P
5.1.3 Test
circuit
Test circuit as in figure 5A is
used
P
5.1.4 Application
of
measuring instrument
Measuring instrument as in
annex D.1 is used
P
5.1.5 Test
procedure
P
5.1.6 Test
measurements
P
Test
voltage
(V) ................................................ : Input: 264 Vac, 60 Hz
⎯
Measured touch current (mA) ........................... : U2
/
500 = 0.17 mA max.
between L&N and secondary
circuit;
U2 / 500 = 0.01 mA max.
U2 / 500 = 0.01 mA max.
between L&N and enclosure
covered with metal foil
⎯
Max. allowed touch current (mA) ...................... : 0.25
mA
⎯
Measured protective conductor current (mA) ... :
⎯
Max. allowed protective conductor current (mA) :
⎯
5.1.7 Equipment
with
touch current exceeding
3.5 mA ............................................................. :
No such equipment
N/A
5.1.8
Touch currents to and from telecommunication
networks and cable distribution systems and
from telecommunication networks
No TNV circuit within the EUT
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distribution system
No TNV circuit within the EUT
N/A
Test
voltage (V) ................................................ :
⎯
Measured touch current (mA) ........................... :
⎯
Max. allowed touch current (mA) ...................... :
⎯
5.1.8.2
Summation of touch currents from
telecommunication networks ..............................:
No TNV circuit within the EUT
N/A
5.2 Electric
strength
P
5.2.1 General
(see appended table 5.2)
P
5.2.2 Test
procedure
(see appended table 5.2)
P
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
(see appended table 5.3)
P
5.3.2 Motors
No such device
N/A
5.3.3
Transformers
(see appended Annex C)
P
5.3.4 Functional
insulation........................................... : Methods a), b) and c)
P