GO PLAY MICRO (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 56

Read Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate online

ATTACHMENT
 
 
National Differences
 
 
 
Page 55 of 58
 
 
Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2007-08-08
                                                                                                               
US National Differences 
 
3.2.3  
Permanent connection of equipment to the mains 
supply by a power supply cord is not permitted, 
except for certain equipment, such as ATMs.  
 
N/A 
3.2.5  
Power supply cords are required to be no longer 
than 4.5 m in length and minimum length shall be 
1.5 m. Flexible power supply cords are required to 
be compatible with Article 400 of the NEC.  
 
N/A 
3.2.9  
Permanently connected equipment must have a 
suitable wiring compartment and wire bending 
space.  
 
N/A 
3.3.3  
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3 mm
2
).  
 
N/A 
3.3.4  
Terminals for permanent wiring, including 
protective earthing terminals, must be suitable for 
U.S wire gauge sizes, rated 125 percent of the 
equipment rating, and be specially marked when 
specified (1.7.7).  
 
N/A 
3.4.2  
Motor control devices are required for cord-
connected equipment with a motor if the 
equipment is rated more than 12 A, or if the motor 
has a nominal voltage rating greater than 120 V, 
or is rated more than 1/3 hp (locked rotor current 
over 43 A).  
No motor control devices. 
N/A 
3.4.8  
Vertically-mounted disconnect switches and 
circuit breakers are required to have the "on" 
position indicated by the handle in the up position.  
No such switches and circuit 
breakers. 
N/A 
3.4.11  
For computer room applications, equipment with 
battery systems capable of supplying 750 VA for 
five minutes are required to have a battery 
disconnect means that may be connected to the 
computer room remote power-off circuit.  
No battery systems. 
N/A 
4.3.12  
The maximum quantity of flammable liquid stored 
in equipment is required to comply with NFPA 30.  
No flammable liquid. 
N/A 
4.3.13.5  
Equipment with lasers is required to meet the 
Code of Federal Regulations 21 CFR 1040.  
No Laser. 
N/A 
4.7  
For computer room applications, automated 
information storage systems with combustible 
media greater than 0.76 m3 (27 cu ft) are 
required to have a provision for connection of 
either automatic sprinklers or a gaseous agent 
extinguishing system with an extended discharge.  
Not automated information 
storage systems.  
N/A 