Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2007-08-08
                                                                                                               
US National Differences 
 
 
US National Differences 
SPECIAL NATIONAL CONDITIONS BASED ON FEDERAL REGULATIONS 
1.1.1  
All equipment is to be designed to allow 
installation in accordance with the National 
Electrical Code (NEC), ANSI/NFPA 70, and when 
applicable, the National Electrical Safety Code, 
IEEE C2.  Also, unless marked or otherwise 
identified, installation is allowed per the Standard 
for the Protection of Electronic Computer/Data-
Processing Equipment, ANSI/NFPA 75.  
The equipment was evaluated 
according to IEC 60950-1.   
The requirements have to be 
checked during the national 
approval. 
N/A 
1.4.14  
For Pluggable Equipment Type A, the protection 
in the installation is assumed to be 20A.  
Class III equipment.  
N/A 
1.5.5  
For lengths exceeding 3.05 m, external 
interconnecting flexible cord and cable 
assemblies are required to be a suitable cable 
type specified in the NEC. For lengths 3.05 m or 
less, external interconnecting flexible cord and 
cable assemblies that are not types specified in 
the NEC are required to have special construction 
features and identification markings.  
Shall be evaluated during the 
national approval for the 
external interconnecting flexible 
cord and cable assemblies. 
 
 
N/A 
1.7.1  
Equipment for use on a.c. mains supply systems 
with a neutral and more than one phase 
conductor (e.g. 120/240 V, 3-wire) require a 
special marking format for electrical ratings.  
Not directly connected to the 
mains.  
N/A 
2.5  
Where a fuse is used to provide Class 2, Limited 
Power Source, or TNV current limiting, it shall not 
be operator-accessible unless it is not 
interchangeable.  
No fuses used for these 
purpose. 
N/A 
2.7.1  
Suitable NEC branch circuit protection rated at 
the maximum circuit rating is required for all 
standard supply outlets and receptacles (such as 
supplied in power distribution units) if the supply 
branch circuit protection is not suitable.  Power 
distribution transformers distributing power at 100 
volts or more, and rated 10 kVA or more, require 
special transformer overcurrent protection.  
No standard supply outlets, 
receptacles, medium-base or 
smaller lampholders provided. 
N/A 
3.2  
Wiring methods (terminals, leads, etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC.  
Not directly connected to the 
mains.  
N/A 
3.2.1  
Power supply cords are required to have 
attachment plugs rated not less than 125 percent 
of the rated current of the equipment.  
 
N/A 
3.2.1.2  
Equipment connected to a centralized d.c. power 
system, and having one pole of the DC mains 
input terminal connected to the main protective 
earthing terminal in the equipment, is required to 
comply with special earthing, wiring, marking and 
installation instruction requirements.  
 
N/A 