ATTACHMENT
National Differences
Page 47 of 58
Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2009-04-16
European Group Differences and National Differences
60728-11).”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60
Hz, for 1 min.
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60
Hz, for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr –
og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres
en galvanisk isolator mellom utstyret og kabel- TV
nettet.”
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr –
og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres
en galvanisk isolator mellom utstyret og kabel- TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medf
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medf
ı
ra risk f
ı
r brand. F
ı
r att undvika
detta skall vid anslutning av utrustningen till
kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
1.7.5
Add the following paragraph to the existing SNC
for Denmark:
for Denmark:
For
CLASS II EQUIPMENT
the socket outlet shall be
in accordance with Standard Sheet DKA 1-4a.
The equipment is Class III
equipment and no socket outlet
provided.
equipment and no socket outlet
provided.
N/A
7.3
Delete the existing SNC for Norway and Sweden
(based on NOTE 1 of IEC 60950-1:2005 + corr.
1).
(based on NOTE 1 of IEC 60950-1:2005 + corr.
1).
Add as new SNC (based on future NOTE 3 of
IEC 60950-1:200X):
IEC 60950-1:200X):
In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex.
1.2.13.14 and 1.7.2.1 of this annex.
The equipment is not
connected to the distribution
systems.
connected to the distribution
systems.
N/A
ZC
ANNEX ZC, NATIONAL DEVIATIONS (EN)
P
1.5.1
Sweden
Delete the A-deviation.
Delete the A-deviation.
Deleted.
N/A
1.7.2.1
Denmark
Delete the A-deviation.
Delete the A-deviation.
Deleted.
N/A
1.7.5
Denmark
Delete the A-deviation.
Delete the A-deviation.
Deleted.
N/A
5.1.7.1
Denmark
Delete the A-deviation.
Delete the A-deviation.
Deleted.
N/A
Click on the first or last page to see other GO PLAY MICRO (serv.man2) service manuals if exist.