Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2010-05-25
Finnish National Differences
FINNISH NATIONAL DIFFERENCES
1.5.9.4
The third dashed sentence is applicable only to
equipment as defined in 6.1.2.2 of this annex.
equipment as defined in 6.1.2.2 of this annex.
N/A
1.7.2.1
CLASS I PLUGGABLE EQUIPMENT TYPE A
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed
mains socket-outlet.
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed
mains socket-outlet.
The marking text shall be as follows:
"Laite on liitettävä suojakoskettimilla varustettuun
pistorasiaan"
pistorasiaan"
N/A
2.3.2
There are additional requirements for the
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
Remark: For 6.1.2.1 see
"European Group Differences
and National Differences".
"European Group Differences
and National Differences".
N/A
2.10.5.13
There are additional requirements for the
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
Remark: For 6.1.2.1 see
"European Group Differences
and National Differences".
"European Group Differences
and National Differences".
N/A
5.1.7.1
TOUCH CURRENT measurement results
exceeding 3,5 mA r.m.s. are permitted only for
the following equipment:
exceeding 3,5 mA r.m.s. are permitted only for
the following equipment:
•
STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
TYPE A that
o
is intended to be used in a
RESTRICTED ACCESS LOCATION
where equipotential bonding has
been applied, for example, in
telecommunication centre; and
RESTRICTED ACCESS LOCATION
where equipotential bonding has
been applied, for example, in
telecommunication centre; and
o
has provision for a permanently
connected PROTECTIVE
EARTHING CONDUCTOR; and
connected PROTECTIVE
EARTHING CONDUCTOR; and
o
is provided with instructions for the
installation of that conductor by a
SERVICE PERSON;
installation of that conductor by a
SERVICE PERSON;
•
STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
TYPE B;
•
STATIONARY PERMANENTLY
CONNECTED EQUIPMENT.
CONNECTED EQUIPMENT.
N/A