Clause
Requirement
−
Test
Result – Remark
Verdict
US National Differences according to CB Bulletin No. 105A, May 2003
2.6.3.3
When subject to impedance testing, protective
earthing and bonding is required to be tested
subject per the specified test conditions that
originate in CSA C22.2 No. 0.4.
No TNV.
N
4.2.8.1
Enclosures around CRTs with a face area
(diagonal dimension) of 160mm or more are
required to reduce the risk of injury due to the
implosion of the CRT.
No CRT.
N
4.3.2
Equipment with handles is required to comply
with special loading tests.
No handles.
N
5.1.8.1.1
Equipment intended to receive
telecommunication ringing signals is required to
comply with a special touch current measurement
tests.
No TNV.
N
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subjected to special
investigation.
No TNV.
N
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
No TNV.
N
6.5
Equipment connected to a telecommunications
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
No TNV.
N
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
No ringing signals.
N
Annex NAB Equipment connected to centralized d.c. power
systems is required to comply with special
earthing, wiring, marking and insulation
requirements in accordance with Annex NAB and
3.6.1.
Supplied from a.c. mains.
N