Page 13 of 84                        Report No. EFSN13070410E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
2.4.3 
Connection of limited current circuits to other 
circuits 
 
N/A 
 
2.5 
Limited power sources 
Also evaluated in approved adapter 
 
a) Inherently limited output 
 
N/A 
 
b) Impedance limited output 
 
N/A 
 
c) Regulating network limited output under normal 
operating and single fault condition 
 
 
d) Overcurrent protective device limited output 
 
N/A 
 
Max. output voltage (V), max. output current (A), 
max. apparent power (VA) ..................................... : 
See table 2.5 
 
 
Current rating of overcurrent protective device (A) .:   
 
 
Use of integrated circuit (IC) current limiters 
 
 
 
2.6 
Provisions for earthing and bonding 
N/A 
2.6.1 
Protective earthing 
 
N/A 
2.6.2 
Functional earthing 
 
N/A 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
N/A 
2.6.3.1 
General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG ....................................................................... : 
 
 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG ....................................................................... : 
 
 
 
Protective current rating (A), cross-sectional area 
(mm
2
), AWG ........................................................... : 
 
 
2.6.3.4 
Resistance of earthing conductors and their 
terminations; resistance (
), voltage drop (V), test 
current (A), duration (min) ...................................... : 
 
N/A
 
2.6.3.5 
Colour of insulation ................................................ :   
N/A
 
2.6.4 
Terminals 
 
N/A
 
2.6.4.1 
General 
 
N/A
 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A
 
 
Rated current (A), type, nominal thread diameter 
(mm) ....................................................................... : 
 
 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
N/A 
Page of 85
Display