Read Harman Kardon DVD 39 (serv.man2) EMC - CB Certificate online
IEC 60065 7ed. (2001)
- Page 2 of 3 -
www.nemko.com
Report No. 98390
13.3 – 13.4
Clearances and Creepage distances
P
Type of
Insulation
Position/
Location
Location
Position/
Location
Location
Operating
Voltage (V)
Clearance
13.3.2
Creepage dist
13.4
Comm.
1
2
Up
Urms
Req.
Measu.
Req.
Measu.
Basic
Live
Neutral 326V 230V 2,0mm
3,7mm 2,5mm 3,7mm 1), 2)
Basic`
Live
Neutral 326V 230V 2,0mm
8,0mm 2,5mm >8,0mm
3)
Reinforce
CY92, pri.
CY92, sec. 326V
230V
4,0mm 6,0mm
5,0mm
6,0mm
1)
Reinforce
CY93, pri.
CY93, sec. 318V
174V
4,0mm 6,2mm
5,0mm
6,2mm
1)
Reinforce
CY94, pri.
CY94, sec. 316V
171V
4,0mm 6,2mm
5,0mm
6,2mm
1)
Reinforce
PC92, pri.
PC92, sec. 356V *) 177V *) 4,0mm 6,5mm
5,0mm
6,5mm
1)
Reinforce
TF91, pin3
TF91, pin7 470V
245V
4,2mm 6,0mm
5,0mm
6,0mm
1)
Reinforce
TF91, pin2
TF91, pin7 335V
176V
4,0mm 6,0mm
5,0mm
6,0mm
1)
Reinforce
TF91, pin4
TF91, pin6 475V *) 247V *) 4,2mm 6,0mm
5,0mm
6,0mm
4)
Reinforce
TF92, pin4
TF92, pin7 316V
171V
4,0mm 6,2mm
5,0mm
6,2mm
1)
Reinforce TF92,
pin2 TF91,pin14
495V
*) 279V *) 4,4mm 6,0mm
6,0mm
6,3mm
4)
*) The highest operating voltage for optocouplers and transformers between primary pins and secondary pins.
Comments: 1) Measured on PCB
2) Before mains fuse (F901).
3) Measured on appliance inlet between live and neutral terminal.
4) Measured on transformer
3) Measured on appliance inlet between live and neutral terminal.
4) Measured on transformer