Test report no. 305945E
Page 5 (14)
5. MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
IN THE FREQUENCY RANGE 0,15 MHz TO 30 MHz
5.1 Operating environment
Temperature: 23
°C
Relative Humidity:
36 %
5.2 Test set-up and test procedure
0,4m
AMN
EUT
> 0,8m
The mains terminal disturbance voltage was measured with the equipment under test (EUT) in a screened
room. The EUT was connected to an artificial mains network (AMN) placed on the floor. The EUT was
placed on a non-metallic table 0,8 m above the metallic, grounded floor and 0,4 m from the reference
ground plane (RGP) wall. The distance to other metallic surfaces was at least 0,8 m.
Amplitude measurements were performed with a quasi-peak detector and, if required, with an average
detector.