Read Harman Kardon DVD 30 (serv.man2) EMC - CB Certificate online
page 6 of 32
Ref.No.:305959-1
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
C5 and C7
P
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
C3 and C4
P
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
This clause is not considered.
Noted.
Reinforced or double insulation between circuits
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
N
Separation by Class
ΙΙ isolating transformer
N
Separation by Class
Ι transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation
≥ 0.4 mm (mm) : N
Reinforced insulation
≥ 0.4 mm (mm) .................... : TR1 P
Thin
sheet
insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
N
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Live wires are double
insulated.
insulated.
Basic insulated sec. wires
cannot reach closer than 3 mm
from live parts.
cannot reach closer than 3 mm
from live parts.
P