SYMPTOM No or intermittent vertical output.
CAUSE
Intermittent solder joint on L501.
ACTION
Resolder joint on L501 as shown in the diagram below.
                                   
Points to resolder on L501
Display

Download Sharp 59CS-03H (serv.man27) Technical Bulletin

Here you can read online and download Sharp 59CS-03H (serv.man27) Technical Bulletin in PDF. 59CS-03H (serv.man27) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp 59CS-03H (serv.man27) CTR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.