Report No.  65335 
 
 
 
 
14.3.3 
Transformer/motor, constructional requirements 
 
Transformer Insulation 
Insulation 
Res.
Test Volt 
Clearances / Creepage distances 
Part No. 
Between 
M Ohms 
kV (60 sec.)
Measured 
Required 
T901
/ CLT9Z021ZE, 
or
      CLT9Z018ZE 
Pri. - Sec. 
> 100 
3KV (rms) 
6,0 / 6,0 mm 
4,4 / 5,6 mm 
 
 
 
 
 
 
- Min. 3,0 mm barrier tape or spacing provided in primary side of the transformer. 
- Min. 6,0 mm barrier tape or spacing provided in secondary side of the transformer. 
All of exposed primary winding wires, and outer pins (7, 15) connected exposed secondary winding  
wires are covered fully by the 0,25mm min. thick. Teflon tubing (PTFE). 
Components / construction 
(T901)
  
Concentric windings on one bobbin. At least 3 layers of ins
ulation between primary and secondary winding.  
Thickness of each layer: 0.025 mm.  Test voltage: 3kV 
 
Max. Working voltage:  540Vpeak / 271Vrms 
Transformer Insulation 
Thick 
(mm)  Material 
Dielectric strength test 
Part No. 
Between 
X Number 
 
60 sec. 
T901
/ CLT9Z021ZE, 
or
      CLT9Z018ZE 
Pr. - Sec. 
0,025 mm x 3 
Polyester  tape 
2 layers tested - Pass *)  
 
Pr. - ic 
0,50 mm min. x 1 
Phenolic bobbin 
1 layer tested - Pass *) 
 
Pr. / Sec. 
0,25 mm min. x 1 
Teflon tube (PTFE) 
1 layer tested - Pass *) 
 
 
 
 
 
*) Test voltage: 3000 Vrms
 
 
17.1 
Torque test to Table 20: 
 
Screw 
Diameter 
With 
Without
Material 
Torque test (Nm) 
Location / function 
(mm) 
Head 
Head 
Screw
Nut 
Fulfilled / Remarks 