DVD 27 (serv.man15) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 51

Read Harman Kardon DVD 27 (serv.man15) EMC - CB Certificate online

 
 
- Page 1 of 6 - 
 
 
www.nemko.com
 
Report No.  65335 
 
 
 
 
 
 
ATTACHMENT: Tables to EN/IEC 60065 7
th
 edition 
 
 
9.1.1.1 
Touch current expressed as voltages U1 and U2 in Annex D 
Location Measured 
U1 
V (peak) 
Measured U1 
V (DC) 
Measured U2 
V (peak) 
Limits : 
U1 Max 35V (peak) 
U1 Max 1.1V (DC) 
U2 Max 0.35V (peak) 
Pole 1 – Video out  terminal 
0,27 V peak 
0,25 V peak 
Pass 
Pole 2 – Video out  terminal 
0,29 V peak 
0,25 V peak 
Pass 
 
 
 
 
 
Comments: 
No other part exceeds 35V peak or 60V dc 
 
 
 
 