IEC 60065, 6th edition : 1998
-
- Page 14 of 32 -
Order No. 200225249
12.4
Drawers (pull test 50 N, 10 s)
No live parts accessible
P
12.5
Antenna coaxial sockets providing
isolation
isolation
None
N
13
CLEARANCES AND CREEPAGE
DISTANCES
DISTANCES
P
13.1.1
Clearances and creepage distances
in accordance with 13.2 (fig. 9);
minimum distance
in accordance with 13.2 (fig. 9);
minimum distance
Reinforced insulation between primary and secondary
traces on PCB. Min. distance is 6.7mm.
traces on PCB. Min. distance is 6.7mm.
P
Reduction applied if the 3 conditions
are met
are met
Yes
P
Reduction applied for Grade 2
winding wire
winding wire
No
N
13.1.2
Use of cemented joints
N
Tests to confirm cemented joints
—
13.2
Clearances and creepage distances
of parts of different polarity directly
connected to the mains, as in fig. 9;
minimum distance
of parts of different polarity directly
connected to the mains, as in fig. 9;
minimum distance
Distance between poles before fuse: min. 5.0mm
P
Clearances and creepage distances
between conductors on printed
circuit boards, one of which may be
conductively connected to the
mains, as in fig. 10 (overheating
only)
between conductors on printed
circuit boards, one of which may be
conductively connected to the
mains, as in fig. 10 (overheating
only)
No overheating of conductors.
N
13.3
Enclosed, enveloped or hermetically
sealed parts: clearances and
creepage distances to Table 4
sealed parts: clearances and
creepage distances to Table 4
N
13.4
Parts filled with insulating
compound, meeting the
requirements of 8.8
compound, meeting the
requirements of 8.8
N
13.5
Type B coated printed circuit boards
complying with IEC 60 664-3 (basic
insulation only)
complying with IEC 60 664-3 (basic
insulation only)
N
14
COMPONENTS
P
14.1
Resistors
N
a) Resistors between hazardous live
parts and accessible metal parts
parts and accessible metal parts
None
N
b) Resistors, other than between
hazardous live parts and accessible
parts
hazardous live parts and accessible
parts
None
N
14.2
Capacitors and RC units
P
Capacitors separately approved
P
14.2.1
Y capacitors tested to IEC 384-14,
2nd edition
2nd edition
Y2 capacitors: C18 and C29
P
14.2.2
X capacitors tested to IEC 384-14,
2nd edition
2nd edition
X2 capacitors: C17, C19, C30 and C31 connected after
the fuse.
the fuse.
P