Read Harman Kardon DVD 25 EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 9 of 32 -
Order No. 200225249
8
CONSTRUCTIONAL
REQUIREMENTS WITH REGARD
TO THE PROTECTION AGAINST
ELECTRIC SHOCK
REQUIREMENTS WITH REGARD
TO THE PROTECTION AGAINST
ELECTRIC SHOCK
P
8.1
Conductive parts covered by
lacquer, paper, untreated textile
oxide films and beads etc.
considered to be bare
lacquer, paper, untreated textile
oxide films and beads etc.
considered to be bare
None
N
8.2
No shock hazard when changing
voltage setting device, fuse-links or
handling drawers etc.
voltage setting device, fuse-links or
handling drawers etc.
No voltage setting device.
Fuses located inside enclosure.
Fuses located inside enclosure.
P
8.3
Insulation of hazardous live parts not
provided by hygroscopic material
provided by hygroscopic material
No hygroscopic material.
P
8.4
No risk of electric shock following
the removal of a cover which can be
removed by hand
the removal of a cover which can be
removed by hand
No cover removable by hand.
P
8.5
Class I equipment
N
Basic insulation between hazardous
live parts and earthed accessible
parts
live parts and earthed accessible
parts
—
Resistors bridging basic insulation
complying with 14.1 a)
complying with 14.1 a)
—
Capacitors bridging basic insulation
complying with 14.2.1 a)
complying with 14.2.1 a)
—
Basic insulation bridged by
components complying with 14.3.4.3
components complying with 14.3.4.3
—
8.6
Class II equipment and Class II constructions within Class I equipment
P
Reinforced or double insulation
between hazardous live parts and
accessible parts
between hazardous live parts and
accessible parts
Complies with the requirements in clause 10 and 13.
P
Components bridging reinforced or
double insulation complying with
14.1 a) or 14.3
double insulation complying with
14.1 a) or 14.3
Basic and supplementary insulation
each being bridged by a capacitor
complying with 14.2.1 a)
each being bridged by a capacitor
complying with 14.2.1 a)
None
N
Reinforced or double insulation
being bridged by 2 capacitors in
series complying with 14.2.1 a)
being bridged by 2 capacitors in
series complying with 14.2.1 a)
None
N
Reinforced or double insulation
being bridged by a single capacitor
complying with 14.2.1 b)
being bridged by a single capacitor
complying with 14.2.1 b)
None
N
8.7
Basic insulation between parts at
35 V to 71 V (peak) a.c. or 60 V to
120 V d.c. and accessible parts
35 V to 71 V (peak) a.c. or 60 V to
120 V d.c. and accessible parts
Secondary voltages below 35V (peak) or 60V dc.
P