DVD 23 (serv.man12) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 39

Read Harman Kardon DVD 23 (serv.man12) EMC - CB Certificate online

 
 
Report No. JSH05110331-001 
Page 38 of 64 
 
9.6 Test protocol 
 
Inject Frequency(MHz) 
Sound(dBuV) 
Picture(dBuV) 
Headphone 
0.15  - 150.00 
 
 
“*” means margin > 6 dB 
 
10. Immunity requirements for audio input and output connectors 
(excluding loudspeaker and headphone) (S2a) 
10.1 Test result 
 
           Pass               Fail              Not Applicable 
 
10.2 Operating environment 
 
Temperature:                           21
°C  
Relative Humidity:                  30%  
 
10.3 Test set-up 
 
The wanted test signal is supplied by generators G1,G2,G3 and G4, via the respective connections A or 
V or S or T and the unwanted signal is supplied by generator G5. Network RCi matches the RF 
disturbance source to the input impedance of the relevant audio terminal and a similar network Rco is 
used to match the output terminals. Mains stop filter MSF is used to inject the unwanted signal at the 
mains terminal and acts as a stop filter for unwanted signals from the mains network. 
 The equipment under test is placed 0.1m above the centre of a metal ground plane of dimensions 2m 
by 1m. The mains lead shall be bundled to a length less than 0.3m and connected in the shortest 
possible way to the mains stop filter MSF. The connection between the metal ground plane and the 
shield of the RF cable at the audio input and output terminals shall be as short as possible.  
The connecting cables are of the 50
Ω coaxial types. 
The unwanted signal was amplitude modulated with 1kHz at 80% depth, supplied by generator G5. 
Page of 65