Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
5.1.8.1.1
of UL 60950, Third Edition” Add to 21st paragraph:
“Telecommunication network that uses outside
cable shall comply with the requirements for
protection against overvoltage from power line
crosses per 6.4 of UL 60950, Third Edition”
Add to 22nd paragraph: “Acoustic tests per 6.5 of
UL 60950, Third Edition for apparatus containing
earphone held against the ear.”
Add to 24th paragraph: “Apparatus shall be
provided with appropriate markings and
instructions as described in Annex NAA of UL
60950, Third Edition.”
Annex D - Figure D.1 & Note delete reference to
IEC 60990 and add reference to ANSI C101. Add
touch current value in MIU where MIU = U2 x 2
(r.m.s. value)
Annex G - Deleted
Annex Q - Add: Safety requirements for video
apparatus for use in health care facilities
Annex R - Add: Safety requirements for
undercabinet apparatus
Annex S - Add: Safety requirements for in-wall
mounted apparatus
Annex T - Add: Safety requirements for apparatus
with projection lamps
Annex U - Add: Safety requirements for
permanently connected apparatus
Annex V - Add: Safety requirements for carts,
stands, and similar apparatus for use with specific
apparatus covered by this standard
Annex W - Add: Construction details for a 0.02-
ohm shunt for use in the peak inrush-current
measurement described in 14.6.11.1
Annex X - Add: Manufacturing and production-line
tests
Annex Y - Add: Normative standards for
components.
“Telecommunication network that uses outside
cable shall comply with the requirements for
protection against overvoltage from power line
crosses per 6.4 of UL 60950, Third Edition”
Add to 22nd paragraph: “Acoustic tests per 6.5 of
UL 60950, Third Edition for apparatus containing
earphone held against the ear.”
Add to 24th paragraph: “Apparatus shall be
provided with appropriate markings and
instructions as described in Annex NAA of UL
60950, Third Edition.”
Annex D - Figure D.1 & Note delete reference to
IEC 60990 and add reference to ANSI C101. Add
touch current value in MIU where MIU = U2 x 2
(r.m.s. value)
Annex G - Deleted
Annex Q - Add: Safety requirements for video
apparatus for use in health care facilities
Annex R - Add: Safety requirements for
undercabinet apparatus
Annex S - Add: Safety requirements for in-wall
mounted apparatus
Annex T - Add: Safety requirements for apparatus
with projection lamps
Annex U - Add: Safety requirements for
permanently connected apparatus
Annex V - Add: Safety requirements for carts,
stands, and similar apparatus for use with specific
apparatus covered by this standard
Annex W - Add: Construction details for a 0.02-
ohm shunt for use in the peak inrush-current
measurement described in 14.6.11.1
Annex X - Add: Manufacturing and production-line
tests
Annex Y - Add: Normative standards for
components.
Noted