Read Harman Kardon DVD 23 (serv.man11) EMC - CB Certificate online
page 45 of 63
Ref. No. : JSH05110330-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Annex A
- Modification: Apparatus intended for outdoor use
or wet locations has any of the following attributes:
a) provided with a means to make it transportable,
b) has a mass less than 35 kg, c) can be battery
operated, d) associated literature states or implies
such use
or wet locations has any of the following attributes:
a) provided with a means to make it transportable,
b) has a mass less than 35 kg, c) can be battery
operated, d) associated literature states or implies
such use
Noted
Add: Apparatus in a), b), or c) above is not
considered for outdoor use or in wet locations if
marked as specified in 5.4..A.5, A.5.1 and A.5.4.1
are deleted.
A.9.1.1 - Add: Touch current test shall be
conducted after the water spray test described in
A.11.1.1 and the touch current shall not be more
than 0.5 MIU when the open-circuit potential
between any accessible part and earth or any
other accessible part is more than 21.2 V peak.
A.10, A10.2, A.10.2.1, and A.10.2.2 are deleted.
A.11.1.1 - Add: Apparatus shall be subjected to
the water spray test according to UL 1571.
A.16.1 - Add: Flexible cords shall be suitable for
outdoor use.
A.20.2.1 - Add: Enclosures for an apparatus
intended for permanent outdoor location shall
comply with requirements for Type 3 enclosures in
UL 50.
considered for outdoor use or in wet locations if
marked as specified in 5.4..A.5, A.5.1 and A.5.4.1
are deleted.
A.9.1.1 - Add: Touch current test shall be
conducted after the water spray test described in
A.11.1.1 and the touch current shall not be more
than 0.5 MIU when the open-circuit potential
between any accessible part and earth or any
other accessible part is more than 21.2 V peak.
A.10, A10.2, A.10.2.1, and A.10.2.2 are deleted.
A.11.1.1 - Add: Apparatus shall be subjected to
the water spray test according to UL 1571.
A.16.1 - Add: Flexible cords shall be suitable for
outdoor use.
A.20.2.1 - Add: Enclosures for an apparatus
intended for permanent outdoor location shall
comply with requirements for Type 3 enclosures in
UL 50.
Noted
Annex B
5th paragraph - add reference to clause 4.2.1.1 in
IEC 62151.
Add to 12th paragraph: “The requirements of
4.2.1.1 shall be replaced by the requirements or
2.3.1 of UL 60950, Third Edition.”
IEC 62151.
Add to 12th paragraph: “The requirements of
4.2.1.1 shall be replaced by the requirements or
2.3.1 of UL 60950, Third Edition.”
Noted
13th paragraph, 2nd dash replace with: “In the
event of a single insulation fault, the voltages on
the TNV-0 circuits, TNV-1 circuits and accessible
conductive parts shall not exceed the values given
in clause 9.1.1.1a of this standard for more than
0.2 s. Moreover, the limits values as given in 11.1
shall not be exceeded. After 0.2 s the voltage
limits of 4.1.2 (35 V peak, or 60 V d.c.) shall
apply.”
event of a single insulation fault, the voltages on
the TNV-0 circuits, TNV-1 circuits and accessible
conductive parts shall not exceed the values given
in clause 9.1.1.1a of this standard for more than
0.2 s. Moreover, the limits values as given in 11.1
shall not be exceeded. After 0.2 s the voltage
limits of 4.1.2 (35 V peak, or 60 V d.c.) shall
apply.”
Noted
Add to 19th paragraph: “Apparatus intended to be
connected to telecommunication networks and
having ringing voltages applied to the apparatus is
subjected to touch current limits in accordance
with clause
connected to telecommunication networks and
having ringing voltages applied to the apparatus is
subjected to touch current limits in accordance
with clause
Noted